array:23 [
  "pii" => "S1695403311003687"
  "issn" => "16954033"
  "doi" => "10.1016/j.anpedi.2011.06.007"
  "estado" => "S300"
  "fechaPublicacion" => "2012-01-01"
  "aid" => "826"
  "copyright" => "Asociación Española de Pediatría"
  "copyrightAnyo" => "2011"
  "documento" => "article"
  "crossmark" => 0
  "subdocumento" => "fla"
  "cita" => "An Pediatr (Barc). 2012;76:11-5"
  "abierto" => array:3 [
    "ES" => false
    "ES2" => false
    "LATM" => false
  ]
  "gratuito" => false
  "lecturas" => array:2 [
    "total" => 10819
    "formatos" => array:3 [
      "EPUB" => 106
      "HTML" => 9985
      "PDF" => 728
    ]
  ]
  "itemSiguiente" => array:18 [
    "pii" => "S1695403311003663"
    "issn" => "16954033"
    "doi" => "10.1016/j.anpedi.2011.06.006"
    "estado" => "S300"
    "fechaPublicacion" => "2012-01-01"
    "aid" => "824"
    "copyright" => "Asociación Española de Pediatría"
    "documento" => "article"
    "crossmark" => 0
    "subdocumento" => "fla"
    "cita" => "An Pediatr (Barc). 2012;76:16-22"
    "abierto" => array:3 [
      "ES" => false
      "ES2" => false
      "LATM" => false
    ]
    "gratuito" => false
    "lecturas" => array:2 [
      "total" => 13666
      "formatos" => array:3 [
        "EPUB" => 112
        "HTML" => 12262
        "PDF" => 1292
      ]
    ]
    "es" => array:13 [
      "idiomaDefecto" => true
      "cabecera" => "<span class="elsevierStyleTextfn">Original</span>"
      "titulo" => "Relaci&#243;n de la relaci&#243;n PaO<span class="elsevierStyleInf">2</span>&#47;FiO<span class="elsevierStyleInf">2</span> y SatO<span class="elsevierStyleInf">2</span>&#47;FiO<span class="elsevierStyleInf">2</span> con la mortalidad y la duraci&#243;n de ingreso en ni&#241;os criticamente enfermos"
      "tienePdf" => "es"
      "tieneTextoCompleto" => "es"
      "tieneResumen" => array:2 [
        0 => "es"
        1 => "en"
      ]
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "16"
          "paginaFinal" => "22"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "en" => array:1 [
          "titulo" => "Relationship between PAO<span class="elsevierStyleInf">2</span>&#47;FIO<span class="elsevierStyleInf">2</span> and SATO<span class="elsevierStyleInf">2</span>&#47;FIO<span class="elsevierStyleInf">2</span> with mortality and duration of admission in critically ill children"
        ]
      ]
      "contieneResumen" => array:2 [
        "es" => true
        "en" => true
      ]
      "contieneTextoCompleto" => array:1 [
        "es" => true
      ]
      "contienePdf" => array:1 [
        "es" => true
      ]
      "resumenGrafico" => array:2 [
        "original" => 0
        "multimedia" => array:7 [
          "identificador" => "fig0005"
          "etiqueta" => "Figura 1"
          "tipo" => "MULTIMEDIAFIGURA"
          "mostrarFloat" => true
          "mostrarDisplay" => false
          "figura" => array:1 [
            0 => array:4 [
              "imagen" => "gr1.jpeg"
              "Alto" => 1000
              "Ancho" => 1618
              "Tamanyo" => 115637
            ]
          ]
          "descripcion" => array:1 [
            "es" => "<p id="spar0045" class="elsevierStyleSimplePara elsevierViewall">Distribuci&#243;n de los pacientes por patolog&#237;as&#46;</p>"
          ]
        ]
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "M&#46;C&#46; Miranda, J&#46; L&#243;pez-Herce, M&#46;C&#46; Mart&#237;nez, A&#46; Carrillo"
          "autores" => array:4 [
            0 => array:2 [
              "nombre" => "M&#46;C&#46;"
              "apellidos" => "Miranda"
            ]
            1 => array:2 [
              "nombre" => "J&#46;"
              "apellidos" => "L&#243;pez-Herce"
            ]
            2 => array:2 [
              "nombre" => "M&#46;C&#46;"
              "apellidos" => "Mart&#237;nez"
            ]
            3 => array:2 [
              "nombre" => "A&#46;"
              "apellidos" => "Carrillo"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "es"
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1695403311003663?idApp=UINPBA00005H"
    "url" => "/16954033/0000007600000001/v1_201304302006/S1695403311003663/v1_201304302006/es/main.assets"
  ]
  "itemAnterior" => array:18 [
    "pii" => "S1695403311003675"
    "issn" => "16954033"
    "doi" => "10.1016/j.anpedi.2011.07.001"
    "estado" => "S300"
    "fechaPublicacion" => "2012-01-01"
    "aid" => "825"
    "copyright" => "Asociaci&#243;n Espa&#241;ola de Pediatr&#237;a"
    "documento" => "article"
    "crossmark" => 0
    "subdocumento" => "fla"
    "cita" => "An Pediatr &#40;Barc&#41;. 2012;76:10&#46;e1-6"
    "abierto" => array:3 [
      "ES" => false
      "ES2" => false
      "LATM" => false
    ]
    "gratuito" => false
    "lecturas" => array:2 [
      "total" => 14278
      "formatos" => array:3 [
        "EPUB" => 95
        "HTML" => 13586
        "PDF" => 597
      ]
    ]
    "es" => array:13 [
      "idiomaDefecto" => true
      "cabecera" => "<span class="elsevierStyleTextfn">Original</span>"
      "titulo" => "Contaje absoluto de linfocitos como factor pron&#243;stico en la leucemia aguda linfobl&#225;stica del ni&#241;o"
      "tienePdf" => "es"
      "tieneTextoCompleto" => "es"
      "tieneResumen" => array:2 [
        0 => "es"
        1 => "en"
      ]
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "10&#46;e1"
          "paginaFinal" => "10&#46;e6"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "en" => array:1 [
          "titulo" => "Absolute lymphocyte count as a prognostic factor in children with acute lymphoblastic leukemia"
        ]
      ]
      "contieneResumen" => array:2 [
        "es" => true
        "en" => true
      ]
      "contieneTextoCompleto" => array:1 [
        "es" => true
      ]
      "contienePdf" => array:1 [
        "es" => true
      ]
      "resumenGrafico" => array:2 [
        "original" => 0
        "multimedia" => array:7 [
          "identificador" => "fig0010"
          "etiqueta" => "Figura 2"
          "tipo" => "MULTIMEDIAFIGURA"
          "mostrarFloat" => true
          "mostrarDisplay" => false
          "figura" => array:1 [
            0 => array:4 [
              "imagen" => "gr2.jpeg"
              "Alto" => 1576
              "Ancho" => 2153
              "Tamanyo" => 150857
            ]
          ]
          "descripcion" => array:1 [
            "es" => "<p id="spar0065" class="elsevierStyleSimplePara elsevierViewall">M&#233;todo de Kaplan Meier para la sobrevida global &#40;SG&#41;&#46; Pacientes con CAL en los d&#237;as 15 y 28 menores de 1&#46;000 c&#233;lulas&#47;&#956;l contra pacientes con CAL mayor o igual de 1&#46;000 c&#233;lulas&#47;&#956;l&#46; &#40;A&#41; Para el CAL-15 la SG fue de 59 vs 89&#37;&#44; respectivamente &#40;p<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>0&#44;001&#41;&#46; &#40;B&#41; Para el CAL-28 la SG fue de 66 vs 86&#37;&#44; respectivamente &#40;p<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>0&#44;01&#41;&#46;</p>"
          ]
        ]
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "A&#46; Anoceto Mart&#237;nez, A&#46; Gonz&#225;lez Otero, E&#46; Guerchicoff de Svarch, A&#46; Arencibia Nu&#241;ez, J&#46;C&#46; Jaime, E&#46; Dorticos, S&#46; Sarduy, L&#46; Gonz&#225;lez"
          "autores" => array:8 [
            0 => array:2 [
              "nombre" => "A&#46;"
              "apellidos" => "Anoceto Mart&#237;nez"
            ]
            1 => array:2 [
              "nombre" => "A&#46;"
              "apellidos" => "Gonz&#225;lez Otero"
            ]
            2 => array:2 [
              "nombre" => "E&#46;"
              "apellidos" => "Guerchicoff de Svarch"
            ]
            3 => array:2 [
              "nombre" => "A&#46;"
              "apellidos" => "Arencibia Nu&#241;ez"
            ]
            4 => array:2 [
              "nombre" => "J&#46;C&#46;"
              "apellidos" => "Jaime"
            ]
            5 => array:2 [
              "nombre" => "E&#46;"
              "apellidos" => "Dorticos"
            ]
            6 => array:2 [
              "nombre" => "S&#46;"
              "apellidos" => "Sarduy"
            ]
            7 => array:2 [
              "nombre" => "L&#46;"
              "apellidos" => "Gonz&#225;lez"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "es"
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1695403311003675?idApp=UINPBA00005H"
    "url" => "/16954033/0000007600000001/v1_201304302006/S1695403311003675/v1_201304302006/es/main.assets"
  ]
  "es" => array:19 [
    "idiomaDefecto" => true
    "cabecera" => "<span class="elsevierStyleTextfn">Original</span>"
    "titulo" => "Medici&#243;n del volumen corriente en ventilaci&#243;n de alta frecuencia"
    "tieneTextoCompleto" => true
    "paginas" => array:1 [
      0 => array:2 [
        "paginaInicial" => "11"
        "paginaFinal" => "15"
      ]
    ]
    "autores" => array:1 [
      0 => array:4 [
        "autoresLista" => "M&#46;J&#46; Solana, J&#46; L&#243;pez-Herce, J&#46; Urbano, S&#46; Menc&#237;a, J&#46; del Castillo, J&#46;M&#46; Bell&#243;n"
        "autores" => array:6 [
          0 => array:2 [
            "nombre" => "M&#46;J&#46;"
            "apellidos" => "Solana"
          ]
          1 => array:4 [
            "nombre" => "J&#46;"
            "apellidos" => "L&#243;pez-Herce"
            "email" => array:1 [
              0 => "pielvi&#64;hotmail&#46;com"
            ]
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">¿</span>"
                "identificador" => "cor0005"
              ]
            ]
          ]
          2 => array:2 [
            "nombre" => "J&#46;"
            "apellidos" => "Urbano"
          ]
          3 => array:2 [
            "nombre" => "S&#46;"
            "apellidos" => "Menc&#237;a"
          ]
          4 => array:2 [
            "nombre" => "J&#46;"
            "apellidos" => "del Castillo"
          ]
          5 => array:2 [
            "nombre" => "J&#46;M&#46;"
            "apellidos" => "Bell&#243;n"
          ]
        ]
        "afiliaciones" => array:1 [
          0 => array:1 [
            "entidad" => "Servicio de Cuidados Intensivos Pedi&#225;tricos&#44; Hospital General Universitario Gregorio Mara&#241;&#243;n&#44; Universidad Complutense&#44; Madrid&#44; Espa&#241;a"
          ]
        ]
        "correspondencia" => array:1 [
          0 => array:3 [
            "identificador" => "cor0005"
            "etiqueta" => "&#8270;"
            "correspondencia" => "Autor para correspondencia&#46;"
          ]
        ]
      ]
    ]
    "titulosAlternativos" => array:1 [
      "en" => array:1 [
        "titulo" => "Measuring tidal volume during paediatric oscillatory and jet high-frequency ventilation"
      ]
    ]
    "resumenGrafico" => array:2 [
      "original" => 0
      "multimedia" => array:7 [
        "identificador" => "fig0010"
        "etiqueta" => "Figura 2"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr2.jpeg"
            "Alto" => 1104
            "Ancho" => 1590
            "Tamanyo" => 102873
          ]
        ]
        "descripcion" => array:1 [
          "es" => "<p id="spar0050" class="elsevierStyleSimplePara elsevierViewall">Relaci&#243;n entre el volumen corriente inspiratorio &#40;VCI&#41; y la frecuencia respiratoria en VAFO en el pulm&#243;n artificial y en los animales&#46;</p> <p id="spar0055" class="elsevierStyleSimplePara elsevierViewall">Existi&#243; una correlaci&#243;n negativa entre ambos par&#225;metros &#40;r<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>&#8722;0&#44;772&#44; p<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>0&#44;02 en cerdos y r<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>&#8722;0&#44;650&#44; p<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>0&#44;03 en el pulm&#243;n artificial&#41;&#46;</p>"
        ]
      ]
    ]
    "textoCompleto" => "<span class="elsevierStyleSections"><span id="sec0005" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle">Introducci&#243;n</span><p id="par0005" class="elsevierStylePara elsevierViewall">La ventilaci&#243;n de alta frecuencia &#40;VAF&#41; es una t&#233;cnica de soporte respiratorio indicada para pacientes con insuficiencia respiratoria hipox&#233;mica y&#47;o hiperc&#225;pnica refractaria a ventilaci&#243;n mec&#225;nica convencional<a class="elsevierStyleCrossRefs" href="#bib0005"><span class="elsevierStyleSup">1&#44;2</span></a>&#46; Existen diferentes tipos de ventilaci&#243;n de alta frecuencia&#44; siendo la ventilaci&#243;n de alta frecuencia oscilatoria &#40;VAFO&#41; la m&#225;s utilizada<a class="elsevierStyleCrossRef" href="#bib0015"><span class="elsevierStyleSup">3</span></a>&#46; El respirador Sensormedics 3100 &#40;Viasys<span class="elsevierStyleSup">R</span>&#41; es el respirador de VAFO m&#225;s utilizado en los ni&#241;os con peso superior a los 2-3<span class="elsevierStyleHsp" style=""></span>kg&#44; ya que puede usarse en un rango amplio de pacientes&#46; La ventilaci&#243;n de alta frecuencia por jet &#40;VAFJ&#41; se utiliza en pacientes sometidos a cirug&#237;a de la v&#237;a a&#233;rea y en neonatos prematuros con enfermedad de membrana hialina<a class="elsevierStyleCrossRefs" href="#bib0020"><span class="elsevierStyleSup">4&#44;5</span></a>&#46;</p><p id="par0010" class="elsevierStylePara elsevierViewall">Los respiradores de ventilaci&#243;n convencional miden el flujo&#44; volumen y la presi&#243;n mediante sensores colocados inmediatamente antes de su conexi&#243;n al tubo endotraqueal&#46; Uno de los mayores problemas de algunos respiradores de VAFO y VAFJ es que no pueden medir el VC&#46; Este hecho unido a la imposibilidad de utilizar capnograf&#237;a dificulta el control de la ventilaci&#243;n durante esta t&#233;cnica&#46; La ventilaci&#243;n solo puede ser monitorizada por la observaci&#243;n de la vibraci&#243;n y la medida de la PCO<span class="elsevierStyleInf">2</span> arterial o transcut&#225;nea<a class="elsevierStyleCrossRefs" href="#bib0030"><span class="elsevierStyleSup">6&#44;7</span></a>&#46;</p><p id="par0015" class="elsevierStylePara elsevierViewall">En la VAF se utilizan vol&#250;menes corrientes bajos de 1 a 2<span class="elsevierStyleHsp" style=""></span>ml&#47;kg&#46; Sin embargo&#44; los cambios en los vol&#250;menes corrientes producen importantes cambios en el intercambio gaseoso ya que el volumen minuto es dependiente de la frecuencia respiratoria por el volumen corriente elevado al cuadrado&#46; Esta es la raz&#243;n por la que la monitorizaci&#243;n del VC es importante en la VAF&#46; A pesar de ello&#44; existen muy pocos estudios que hayan estudiado la capacidad de los espir&#243;metros para medir el VC en ni&#241;os o modelos animales pedi&#225;tricos con VAFO<a class="elsevierStyleCrossRefs" href="#bib0040"><span class="elsevierStyleSup">8&#44;9</span></a>&#44; y ninguno lo ha estudiado con la VAFJ&#46;</p><p id="par0020" class="elsevierStylePara elsevierViewall">El objetivo de este estudio ha sido estudiar si un espir&#243;metro basado en el tubo de Pitot puede medir los vol&#250;menes corrientes generados durante la VAFO y la VAFJ y analizar el efecto de la modificaci&#243;n de los distintos par&#225;metros de la ventilaci&#243;n de alta frecuencia &#40;amplitud&#44; frecuencia y presi&#243;n media&#41; sobre el volumen corriente&#46;</p></span><span id="sec0010" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle">Material y m&#233;todos</span><p id="par0025" class="elsevierStylePara elsevierViewall">El estudio se llevo a cabo en dos fases&#58; inicialmente sobre simuladores de pulm&#243;n artificial pedi&#225;trico y posteriormente en un modelo animal infantil&#46; El protocolo fue aprobado por el Comit&#233; hospitalario de &#201;tica e Investigaci&#243;n&#46;</p><p id="par0030" class="elsevierStylePara elsevierViewall">Estudio in experimental in vitro&#46; Se utilizaron dos pulmones artificiales&#44; uno adulto-pedi&#225;trico &#40;Adult&#47;Pediatric Demonstration Lung&#44; Ingmar Medical<span class="elsevierStyleSup">R</span>&#41; y otro neonatal &#40;Neonatal Demonstration Lung model&#44; Drager<span class="elsevierStyleSup">R</span>&#41;&#44; conectados a un respirador de VAFO &#40;Sensormedics 3100 B&#44; &#40;Viasys<span class="elsevierStyleSup">R</span>&#41; y a otro de VAFJ &#40;Paravent PAT<span class="elsevierStyleInf">e</span><span class="elsevierStyleBold">&#44;</span> Respiromed&#44; Czech Republic&#41;&#46; Entre ambos se coloc&#243; un espir&#243;metro D-Fend &#40;Datex-Ohmeda&#41; que mide el volumen corriente inspirado &#40;VCI&#41;&#44; volumen corriente espirado &#40;VCE&#41;&#44; las presiones y flujos conectado a un m&#243;dulo de funci&#243;n respiratoria de un monitor Datex Ohmeda S5 &#40;General Electric&#41;&#46; El espir&#243;metro D-Fend calcula el volumen corriente bas&#225;ndose en el principio de Bernoulli seg&#250;n el cual la diferencia de presi&#243;n que se produce entre los extremos del espir&#243;metro produce una se&#241;al de voltaje que es proporcional al flujo&#46; Este m&#233;todo ha sido validado para medir el VC en modelos adultos de VAFO<a class="elsevierStyleCrossRef" href="#bib0050"><span class="elsevierStyleSup">10</span></a>&#46;</p><p id="par0035" class="elsevierStylePara elsevierViewall">Modelo animal&#58; el experimento se repiti&#243; en un modelo animal infantil &#40;3 cerdos minipig de pesos entre 7&#44;5 y 14<span class="elsevierStyleHsp" style=""></span>kg&#41;&#46; Durante el estudio se siguieron las normas internacionales para el cuidado de los animales de experimentaci&#243;n&#44; recibiendo sedaci&#243;n con propofol&#44; fentanilo y relajaci&#243;n con atracurio&#46; Los cerdos fueron intubados con un tubo endotraqueal de di&#225;metro interno 4&#44;5<span class="elsevierStyleHsp" style=""></span>mm y conectados mediante un espir&#243;metro D-Fend a los respiradores&#46; Se canalizaron la vena y arteria femorales para la administraci&#243;n de medicaci&#243;n y extracci&#243;n de gasometr&#237;as&#46;</p><p id="par0040" class="elsevierStylePara elsevierViewall">Protocolo experimental&#58; en la VAFO se utilizaron los siguientes par&#225;metros&#58; flujo 20 L&#47;min&#44; porcentaje de tiempo inspiratorio &#40;&#37;Ti&#41; 33&#37; y fracci&#243;n inspirada de ox&#237;geno &#40;FiO<span class="elsevierStyleInf">2</span>&#41; 60&#37;&#46; Se realizaron mediciones cambiando la frecuencia respiratoria &#40;FR&#41; &#40;6&#44;7&#44;9 y 10 herzios &#40;respiraciones&#47;segundo&#41; &#40;Hz&#41;&#44; la amplitud &#40;AMP&#41; 20&#44;25&#44;30&#44;35&#44;40&#44;45&#44;50&#44;55&#44;60&#44;65 y 70<span class="elsevierStyleHsp" style=""></span>cmH<span class="elsevierStyleInf">2</span>O&#41; y la presi&#243;n media en la v&#237;a a&#233;rea &#40;PMVA&#41; 15&#44; 25 y 30<span class="elsevierStyleHsp" style=""></span>cmH<span class="elsevierStyleInf">2</span>O&#41; en cada uno de los pulmones artificiales y en el cerdo&#46;</p><p id="par0045" class="elsevierStylePara elsevierViewall">Con la VAFJ se mantuvo una relaci&#243;n I&#47;E constante de 1&#47;2 y se realizaron mediciones cambiando la FR &#40;40&#44; 120 y 180<span class="elsevierStyleHsp" style=""></span>Hz&#41; y la presi&#243;n &#40;15&#44;20&#44;25 y 30<span class="elsevierStyleHsp" style=""></span>cmH<span class="elsevierStyleInf">2</span>O&#41;&#46;</p><p id="par0050" class="elsevierStylePara elsevierViewall">Se registraron los valores de VCI&#44; VCE&#44; presi&#243;n pico inspiratoria &#40;PIP&#41;&#44; presi&#243;n espiratoria final &#40;PEEP&#41; y PMVA&#46; Todas las medidas se realizaron dos veces&#46; Los experimentos se llevaron a cabo en todos los casos en las mismas condiciones de humedad&#44; presi&#243;n y temperatura&#46;</p><p id="par0055" class="elsevierStylePara elsevierViewall">Los resultados fueron analizados con el programa SPSS versi&#243;n 16&#46;0&#44; utiliz&#225;ndose una prueba de correlaci&#243;n parcial para estudiar la correlaci&#243;n entre los par&#225;metros</p></span><span id="sec0015" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle">Resultados</span><span id="sec0020" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle">Ventilaci&#243;n de alta frecuencia oscilatoria</span><p id="par0060" class="elsevierStylePara elsevierViewall">El espir&#243;metro fue capaz de medir los vol&#250;menes en el pulm&#243;n artificial pedi&#225;trico-adulto pero no en el pulm&#243;n de prueba neonatal&#46; El espir&#243;metro tampoco fue capaz de medir el volumen corriente con amplitudes elevadas entre los 55 y 65<span class="elsevierStyleHsp" style=""></span>cmH<span class="elsevierStyleInf">2</span>O ni con PMVA m&#225;s altas de 30<span class="elsevierStyleHsp" style=""></span>cmH<span class="elsevierStyleInf">2</span>O&#46; En los animales el espir&#243;metro solo detect&#243; un VC de 8<span class="elsevierStyleHsp" style=""></span>ml o superior&#44; y cuando la amplitud era igual o superior a 35<span class="elsevierStyleHsp" style=""></span>cmH<span class="elsevierStyleInf">2</span>O&#46;</p><p id="par0065" class="elsevierStylePara elsevierViewall">Tanto en los pulmones artificiales como en los animales el VCI y VCE aumentaron al aumentar la amplitud &#40;<a class="elsevierStyleCrossRef" href="#fig0005">fig&#46; 1</a>&#41;&#44; existiendo una buena correlaci&#243;n&#44; que fue independiente de la frecuencia y la PMVA programadas&#46; Por el contrario&#44; el VCI y VCE fueron disminuyendo al aumentar la frecuencia existiendo una correlaci&#243;n inversa estad&#237;sticamente significativa &#40;<a class="elsevierStyleCrossRef" href="#fig0010">fig&#46; 2</a>&#41;&#46; Tambi&#233;n existi&#243; una buena correlaci&#243;n entre la PMVA programada y las presiones registradas por el espir&#243;metro &#40;r<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>0&#44;960&#44; p<span class="elsevierStyleHsp" style=""></span>&#60;<span class="elsevierStyleHsp" style=""></span>0&#44;001&#41;&#46;</p><elsevierMultimedia ident="fig0005"></elsevierMultimedia><elsevierMultimedia ident="fig0010"></elsevierMultimedia></span><span id="sec0025" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle">Ventilaci&#243;n de alta frecuencia por jet</span><p id="par0070" class="elsevierStylePara elsevierViewall">El espir&#243;metro midi&#243; el VC durante la VAFJ en el pulm&#243;n adulto-pedi&#225;trico&#44; pulm&#243;n neonatal y en los cerdos con todas las presiones y frecuencias programadas&#46; En ambos modelos el VCI y VCE aumentaron con la presi&#243;n y presentaron una buena correlaci&#243;n entre ambos&#44; independientemente de la frecuencia y la presi&#243;n programada &#40;<a class="elsevierStyleCrossRef" href="#fig0015">fig&#46; 3</a>&#41;&#46; El VCI y VCE disminuyeron al aumentar la frecuencia&#44; existiendo una correlaci&#243;n inversa estad&#237;sticamente significativa &#40;<a class="elsevierStyleCrossRef" href="#fig0020">fig&#46; 4</a>&#41;&#46; Existi&#243; una buena correlaci&#243;n entre la presi&#243;n programada y la medida por el espir&#243;metro &#40;r<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>0&#44;970&#44; p<span class="elsevierStyleHsp" style=""></span>&#60;<span class="elsevierStyleHsp" style=""></span>0&#44;001&#41;&#46;</p><elsevierMultimedia ident="fig0015"></elsevierMultimedia><elsevierMultimedia ident="fig0020"></elsevierMultimedia></span></span><span id="sec0030" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle">Discusi&#243;n</span><p id="par0075" class="elsevierStylePara elsevierViewall">La VAFO es un tipo de ventilaci&#243;n mec&#225;nica que favorece el intercambio gaseoso mediante la utilizaci&#243;n de vol&#250;menes peque&#241;os &#40;entre 1-2<span class="elsevierStyleHsp" style=""></span>ml&#47;kg&#41; y frecuencias suprafisiol&#243;gicas &#40;3-20 hertzios&#44; ciclos&#47;sg&#41; protegiendo al pulm&#243;n de la p&#233;rdida del reclutamiento alveolar y la sobredistensi&#243;n<a class="elsevierStyleCrossRefs" href="#bib0045"><span class="elsevierStyleSup">9&#44;11</span></a>&#46;</p><p id="par0080" class="elsevierStylePara elsevierViewall">Los dispositivos de VAFO generan ondas de presi&#243;n de alta amplitud a nivel proximal que se van atenuando por la resistencia que ejerce el circuito&#44; de manera que al alveolo solamente le llegan ondas de baja amplitud evit&#225;ndose as&#237; el barotrauma<a class="elsevierStyleCrossRef" href="#bib0060"><span class="elsevierStyleSup">12</span></a>&#46;</p><p id="par0085" class="elsevierStylePara elsevierViewall">La VAFJ consigue el intercambio gaseoso por medio de un efecto Venturi&#44; administrando peque&#241;os pulsos de gas caliente a trav&#233;s de un inyector que est&#225; conectado al tubo endotraqueal del paciente<a class="elsevierStyleCrossRef" href="#bib0055"><span class="elsevierStyleSup">11</span></a>&#46; La frecuencia respiratoria utilizada en la VAFJ es elevada pero significativamente inferior a la de la VAFO&#46; En este respirador la programaci&#243;n de la amplitud se realiza indirectamente por medio de la presi&#243;n&#46; En este tipo de ventilaci&#243;n la espiraci&#243;n es pasiva&#46;</p><p id="par0090" class="elsevierStylePara elsevierViewall">Sin embargo&#44; en algunos respiradores como el Sensor Medics 3100 no es posible monitorizar el volumen corriente entregado al paciente existiendo por tanto riesgo de hipo o hiperventilaci&#243;n&#46;</p><p id="par0095" class="elsevierStylePara elsevierViewall">El volumen corriente generado en la VAFO se ha tratado de estimar mediante neumotac&#243;grafos&#44; pero estos requieren m&#250;ltiples calibraciones que dependen de la frecuencia oscilatoria&#44; la composici&#243;n del gas&#44; la amplitud&#44; la temperatura y la humedad<a class="elsevierStyleCrossRef" href="#bib0050"><span class="elsevierStyleSup">10</span></a>&#46; Por esta raz&#243;n&#44; se han desarrollado nuevos sistemas como la tomograf&#237;a computarizada<a class="elsevierStyleCrossRef" href="#bib0065"><span class="elsevierStyleSup">13</span></a>&#44; el anem&#243;metro<a class="elsevierStyleCrossRefs" href="#bib0050"><span class="elsevierStyleSup">10&#44;14</span></a>&#44; los ultrasonidos o el tubo de Pitot<a class="elsevierStyleCrossRef" href="#bib0050"><span class="elsevierStyleSup">10</span></a>&#46; En este &#250;ltimo m&#233;todo se basa el espir&#243;metro que hemos empleado en nuestro estudio&#46; No existen estudios previos que hayan medido el VC generado en la VAFJ&#46;</p><p id="par0100" class="elsevierStylePara elsevierViewall">En nuestro estudio hemos demostrado que el espir&#243;metro D-Fend puede monitorizar el volumen corriente durante la VAFO y el VAFJ en modelos pedi&#225;tricos en determinadas condiciones&#46;</p><p id="par0105" class="elsevierStylePara elsevierViewall">Estudios in vitro<a class="elsevierStyleCrossRefs" href="#bib0035"><span class="elsevierStyleSup">7&#44;10&#44;15</span></a> e in vivo con animales<a class="elsevierStyleCrossRefs" href="#bib0040"><span class="elsevierStyleSup">8&#44;9&#44;13</span></a> han demostrado el efecto de la amplitud y la frecuencia sobre el volumen corriente en la VAFO&#46; Nuestros resultados son similares&#44; ya que el VC aument&#243; con el incremento de la amplitud y disminuy&#243; con el incremento de la frecuencia tanto en los pulmones artificiales como en los animales&#46; Hay que tener en cuenta que la f&#243;rmula del volumen minuto es diferente en la ventilaci&#243;n de alta frecuencia y en la ventilaci&#243;n convencional&#44; y que en la VAF los incrementos de FR disminuyen el VC y secundariamente el volumen minuto&#46;</p><p id="par0110" class="elsevierStylePara elsevierViewall">Nuestros resultados tambi&#233;n muestran que en la VAFJ el VC aumenta con la presi&#243;n&#44; ya que es el equivalente de la amplitud en este tipo de ventilaci&#243;n&#44; y disminuye con la frecuencia&#46;</p><p id="par0115" class="elsevierStylePara elsevierViewall">Por otra parte&#44; la elevada correlaci&#243;n entre la PMVA programada y las presiones medidas por el espir&#243;metro sugieren que el espir&#243;metro D-Fend puede servir para monitorizar las presiones generadas durante la VAFO y la VAFJ&#46;</p><p id="par0120" class="elsevierStylePara elsevierViewall">El estudio tiene algunas limitaciones&#46; El espir&#243;metro no fue capaz de medir el VC en el pulm&#243;n neonatal probablemente por su incapacidad de medir VC bajos&#46; Esta probablemente es la raz&#243;n por la que tampoco logr&#243; medir el VC cuando se utilizaron amplitudes menores de 35<span class="elsevierStyleHsp" style=""></span>cmH<span class="elsevierStyleInf">2</span>O en los animales&#46; Por otra parte&#44; las especificaciones del monitor establecen que el m&#237;nimo VC detectado es de 15<span class="elsevierStyleHsp" style=""></span>ml&#46; Sin embargo&#44; en nuestros experimentos logr&#243; medir VC a partir de 8<span class="elsevierStyleHsp" style=""></span>ml&#46; Este hecho limita la utilizaci&#243;n de este monitor en los neonatos y los lactantes de bajo peso&#46; Son necesarios estudios que confirmen nuestros resultados en ni&#241;os de diferentes edades y pesos&#46;</p><p id="par0125" class="elsevierStylePara elsevierViewall">Concluimos que el espir&#243;metro D-Fend puede medir el volumen corriente durante la VAFO y la VAFJ&#46; Sin embargo no es capaz de medir VC menores de 8 o cuando se utilizan amplitudes o presiones elevadas&#46;</p></span><span id="sec0040" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle">Financiaci&#243;n</span><p id="par0135" class="elsevierStylePara elsevierViewall">El estudio ha sido realizado con la ayuda de la Red de Salud Materno Infantil y del Desarrollo SAMID RD08&#47;0072 del Instituto Carlos III del VI programa marco nacional 2008-2011&#46;</p></span><span id="sec0035" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle">Conflicto de intereses</span><p id="par0130" class="elsevierStylePara elsevierViewall">Los autores declaran no tener ning&#250;n conflicto de intereses&#46;</p></span></span>"
    "textoCompletoSecciones" => array:1 [
      "secciones" => array:11 [
        0 => array:2 [
          "identificador" => "xres106328"
          "titulo" => array:5 [
            0 => "Resumen"
            1 => "Objetivo"
            2 => "M&#233;todos"
            3 => "Resultados"
            4 => "Conclusiones"
          ]
        ]
        1 => array:2 [
          "identificador" => "xpalclavsec93715"
          "titulo" => "Palabras clave"
        ]
        2 => array:2 [
          "identificador" => "xres106329"
          "titulo" => array:5 [
            0 => "Abstract"
            1 => "Objective"
            2 => "Methods"
            3 => "Results"
            4 => "Conclusions"
          ]
        ]
        3 => array:2 [
          "identificador" => "xpalclavsec93716"
          "titulo" => "Keywords"
        ]
        4 => array:2 [
          "identificador" => "sec0005"
          "titulo" => "Introducci&#243;n"
        ]
        5 => array:2 [
          "identificador" => "sec0010"
          "titulo" => "Material y m&#233;todos"
        ]
        6 => array:3 [
          "identificador" => "sec0015"
          "titulo" => "Resultados"
          "secciones" => array:2 [
            0 => array:2 [
              "identificador" => "sec0020"
              "titulo" => "Ventilaci&#243;n de alta frecuencia oscilatoria"
            ]
            1 => array:2 [
              "identificador" => "sec0025"
              "titulo" => "Ventilaci&#243;n de alta frecuencia por jet"
            ]
          ]
        ]
        7 => array:2 [
          "identificador" => "sec0030"
          "titulo" => "Discusi&#243;n"
        ]
        8 => array:2 [
          "identificador" => "sec0040"
          "titulo" => "Financiaci&#243;n"
        ]
        9 => array:2 [
          "identificador" => "sec0035"
          "titulo" => "Conflicto de intereses"
        ]
        10 => array:1 [
          "titulo" => "Bibliograf&#237;a"
        ]
      ]
    ]
    "pdfFichero" => "main.pdf"
    "tienePdf" => true
    "fechaRecibido" => "2011-03-07"
    "fechaAceptado" => "2011-06-25"
    "PalabrasClave" => array:2 [
      "es" => array:1 [
        0 => array:4 [
          "clase" => "keyword"
          "titulo" => "Palabras clave"
          "identificador" => "xpalclavsec93715"
          "palabras" => array:6 [
            0 => "Ventilaci&#243;n de alta frecuencia"
            1 => "Ventilaci&#243;n de alta frecuencia por jet"
            2 => "Monitorizaci&#243;n respiratoria"
            3 => "Espir&#243;metro"
            4 => "Volumen corriente"
            5 => "Ni&#241;os"
          ]
        ]
      ]
      "en" => array:1 [
        0 => array:4 [
          "clase" => "keyword"
          "titulo" => "Keywords"
          "identificador" => "xpalclavsec93716"
          "palabras" => array:6 [
            0 => "High-frequency ventilation"
            1 => "High-frequency jet ventilation"
            2 => "Respiratory monitoring"
            3 => "Spirometer"
            4 => "Tidal volume"
            5 => "Paediatrics"
          ]
        ]
      ]
    ]
    "tieneResumen" => true
    "resumen" => array:2 [
      "es" => array:2 [
        "titulo" => "Resumen"
        "resumen" => "<span class="elsevierStyleSectionTitle">Objetivo</span><p id="spar0005" class="elsevierStyleSimplePara elsevierViewall">Valorar si un espir&#243;metro puede medir el volumen corriente en ventilaci&#243;n de alta frecuencia oscilatoria &#40;VAFO&#41; y por jet &#40;VAFJ&#41; y analizar el efecto de los cambios en los par&#225;metros del respirador&#46;</p> <span class="elsevierStyleSectionTitle">M&#233;todos</span><p id="spar0010" class="elsevierStyleSimplePara elsevierViewall">Se realiz&#243; un estudio con pulmones de prueba pedi&#225;tricos y en cerdos&#46; Para la VAFO se utiliz&#243; el respirador Sensormedics 3100B<span class="elsevierStyleSup">R</span> y para la VAFJ el respirador Paravent Pat<span class="elsevierStyleInf">e</span><span class="elsevierStyleSup">R</span>&#46; La medici&#243;n del volumen corriente &#40;VC&#41; se realiz&#243; con un espir&#243;metro D-Fend&#46; Se realizaron cambios en la frecuencia&#44; amplitud y presi&#243;n media en la v&#237;a a&#233;rea &#40;PMVA&#41;&#44; registr&#225;ndose los cambios en el VC y las presiones&#46;</p> <span class="elsevierStyleSectionTitle">Resultados</span><p id="spar0015" class="elsevierStyleSimplePara elsevierViewall">El espir&#243;metro midi&#243; el VC en los pulmones de prueba y en los cerdos&#44; pero no pudo medir VC menores de 8<span class="elsevierStyleHsp" style=""></span>ml&#44; cuando la amplitud era mayor de 55<span class="elsevierStyleHsp" style=""></span>cmH<span class="elsevierStyleInf">2</span>O o la PMVA mayor de 30<span class="elsevierStyleHsp" style=""></span>cmH<span class="elsevierStyleInf">2</span>O&#46; En la VAFO existi&#243; una correlaci&#243;n entre la amplitud y el VC y en la VAFJ entre la presi&#243;n y el VC&#46; En ambos respiradores existi&#243; una correlaci&#243;n negativa entre la frecuencia y el VC&#46;</p> <span class="elsevierStyleSectionTitle">Conclusiones</span><p id="spar0020" class="elsevierStyleSimplePara elsevierViewall">El espir&#243;metro D-Fend puede medir el volumen corriente durante la VAFO y la VAFJ&#44; pero no es capaz de medir VC menores de 8 o cuando se utilizan amplitudes o presiones elevadas&#46;</p>"
      ]
      "en" => array:2 [
        "titulo" => "Abstract"
        "resumen" => "<span class="elsevierStyleSectionTitle">Objective</span><p id="spar0025" class="elsevierStyleSimplePara elsevierViewall">To ascertain whether a spirometer can measure tidal volume &#40;TV&#41; during high frequency oscillatory ventilation &#40;HFOV&#41; and high frequency jet ventilation &#40;HFJV&#41;&#44; and to analyse the effect of changes in ventilator settings&#46;</p> <span class="elsevierStyleSectionTitle">Methods</span><p id="spar0030" class="elsevierStyleSimplePara elsevierViewall">The study was performed with paediatric porcine lung models submitted to HFOV with a Sensormedics 3100 ventilator and HFJV with a Paravent Pat<span class="elsevierStyleInf">e</span><span class="elsevierStyleSup">R</span> ventilator connected to a D-Fend spirometer&#46; Programmed frequency&#44; amplitude&#44; and mean airway pressure &#40;MAP&#41; were changed in the ventilator&#44; and TV and pressures were recorded using the spirometer&#46;</p> <span class="elsevierStyleSectionTitle">Results</span><p id="spar0035" class="elsevierStyleSimplePara elsevierViewall">The spirometer measured TV in the paediatric lung models and piglets&#44; but could not measure TV less than 8<span class="elsevierStyleHsp" style=""></span>ml&#44; when the pressure amplitude was higher than 55<span class="elsevierStyleHsp" style=""></span>cmH<span class="elsevierStyleInf">2</span>O or the MAP was higher than 30<span class="elsevierStyleHsp" style=""></span>cmH<span class="elsevierStyleInf">2</span>O&#46; With HFOV there was a correlation between amplitude and tidal volume&#44; and a positive correlation between pressure and TV with HFJV&#46; With both respirators there was a negative correlation between frequency and TV&#46;</p> <span class="elsevierStyleSectionTitle">Conclusions</span><p id="spar0040" class="elsevierStyleSimplePara elsevierViewall">The D-Fend spirometer can measure tidal volume and pressure during HFOV and HFJV&#46; However&#44; it does not work with volumes lower than 8<span class="elsevierStyleHsp" style=""></span>ml&#44; and high amplitude or mean airway pressure&#46;</p>"
      ]
    ]
    "multimedia" => array:4 [
      0 => array:7 [
        "identificador" => "fig0005"
        "etiqueta" => "Figura 1"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr1.jpeg"
            "Alto" => 1132
            "Ancho" => 1576
            "Tamanyo" => 107970
          ]
        ]
        "descripcion" => array:1 [
          "es" => "<p id="spar0045" class="elsevierStyleSimplePara elsevierViewall">Relaci&#243;n entre el volumen corriente inspiratorio &#40;VCI&#41; y la amplitud en VAFO en el pulm&#243;n artificial y en los animales&#46; Existi&#243; una elevada correlaci&#243;n entre ambos par&#225;metros &#40;r<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>0&#44;855&#44; p<span class="elsevierStyleHsp" style=""></span>&#60;<span class="elsevierStyleHsp" style=""></span>0&#44;001 en cerdos y r<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>0&#44;703 p<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>0&#44;002 en el pulm&#243;n artificial&#41;&#46;</p>"
        ]
      ]
      1 => array:7 [
        "identificador" => "fig0010"
        "etiqueta" => "Figura 2"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr2.jpeg"
            "Alto" => 1104
            "Ancho" => 1590
            "Tamanyo" => 102873
          ]
        ]
        "descripcion" => array:1 [
          "es" => "<p id="spar0050" class="elsevierStyleSimplePara elsevierViewall">Relaci&#243;n entre el volumen corriente inspiratorio &#40;VCI&#41; y la frecuencia respiratoria en VAFO en el pulm&#243;n artificial y en los animales&#46;</p> <p id="spar0055" class="elsevierStyleSimplePara elsevierViewall">Existi&#243; una correlaci&#243;n negativa entre ambos par&#225;metros &#40;r<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>&#8722;0&#44;772&#44; p<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>0&#44;02 en cerdos y r<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>&#8722;0&#44;650&#44; p<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>0&#44;03 en el pulm&#243;n artificial&#41;&#46;</p>"
        ]
      ]
      2 => array:7 [
        "identificador" => "fig0015"
        "etiqueta" => "Figura 3"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr3.jpeg"
            "Alto" => 1097
            "Ancho" => 1618
            "Tamanyo" => 83319
          ]
        ]
        "descripcion" => array:1 [
          "es" => "<p id="spar0060" class="elsevierStyleSimplePara elsevierViewall">Relaci&#243;n entre el volumen corriente inspiratorio &#40;VCI&#41; y el pico de presi&#243;n en VAFJ en el pulm&#243;n artificial y en los animales&#46;</p> <p id="spar0065" class="elsevierStyleSimplePara elsevierViewall">Existi&#243; una elevada correlaci&#243;n entre ambos par&#225;metros &#40;r<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>0&#44;928&#44; p<span class="elsevierStyleHsp" style=""></span>&#60;<span class="elsevierStyleHsp" style=""></span>0&#44;001 en cerdos y r<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>0&#44;772&#44; p<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>0&#44;03 en el pulm&#243;n artificial&#41;&#46;</p>"
        ]
      ]
      3 => array:7 [
        "identificador" => "fig0020"
        "etiqueta" => "Figura 4"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr4.jpeg"
            "Alto" => 1125
            "Ancho" => 1618
            "Tamanyo" => 87311
          ]
        ]
        "descripcion" => array:1 [
          "es" => "<p id="spar0070" class="elsevierStyleSimplePara elsevierViewall">Relaci&#243;n entre el volumen corriente inspiratorio &#40;VCI&#41; y la frecuencia respiratoria en VAFJ en el pulm&#243;n artificial y en los animales&#46;</p> <p id="spar0075" class="elsevierStyleSimplePara elsevierViewall">Existi&#243; una correlaci&#243;n negativa entre ambos par&#225;metros &#40;r<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>&#8722;0&#44;924&#44; p<span class="elsevierStyleHsp" style=""></span>&#60;<span class="elsevierStyleHsp" style=""></span>0&#44;001 en cerdos y r<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>&#8722;0&#44;934&#44; p<span class="elsevierStyleHsp" style=""></span>&#60;<span class="elsevierStyleHsp" style=""></span>0&#44;001 en el pulm&#243;n artificial&#41;&#46;</p>"
        ]
      ]
    ]
    "bibliografia" => array:2 [
      "titulo" => "Bibliograf&#237;a"
      "seccion" => array:1 [
        0 => array:2 [
          "identificador" => "bibs0005"
          "bibliografiaReferencia" => array:15 [
            0 => array:3 [
              "identificador" => "bib0005"
              "etiqueta" => "1"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Uso de ventilaci&#243;n de alta frecuencia oscilatoria en pacientes pedi&#225;tricos"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "A&#46; Donoso"
                            1 => "J&#46; Le&#243;n"
                            2 => "G&#46; Rojas"
                            3 => "C&#46; Valverde"
                            4 => "M&#46; Escobar"
                            5 => "M&#46; Ram&#237;rez"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "Rev Chil Pediatr"
                        "fecha" => "2002"
                        "volumen" => "73"
                        "paginaInicial" => "461"
                        "paginaFinal" => "470"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            1 => array:3 [
              "identificador" => "bib0010"
              "etiqueta" => "2"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Ventilaci&#243;n de alta frecuencia oscilatoria en pacientes pedi&#225;tricos"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:5 [
                            0 => "A&#46; Donoso"
                            1 => "P&#46; Cruces"
                            2 => "J&#46; Le&#243;n"
                            3 => "M&#46; Ram&#237;rez"
                            4 => "J&#46; Camacho"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "Rev Chil Enferm Respir"
                        "fecha" => "2006"
                        "volumen" => "22"
                        "paginaInicial" => "21"
                        "paginaFinal" => "30"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            2 => array:3 [
              "identificador" => "bib0015"
              "etiqueta" => "3"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Ventilaci&#243;n de alta frecuencia en el reci&#233;n nacido&#58; Un soporte respiratorio necesario"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:1 [
                            0 => "A&#46; Bancalari"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "Rev Chil Pediatr"
                        "fecha" => "2003"
                        "volumen" => "74"
                        "paginaInicial" => "475"
                        "paginaFinal" => "486"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            3 => array:3 [
              "identificador" => "bib0020"
              "etiqueta" => "4"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Rescue high frequency jet ventilation versus conventional ventilation for severe pulmonary dysfunction in preterm infants"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:2 [
                            0 => "V&#46;H&#46; Joshi"
                            1 => "T&#46; Bhuta"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "Cochrane Database Syst Rev"
                        "fecha" => "2006"
                        "volumen" => "25"
                        "paginaInicial" => "CD000437"
                        "itemHostRev" => array:3 [
                          "pii" => "S0001731011000159"
                          "estado" => "S300"
                          "issn" => "00017310"
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            4 => array:3 [
              "identificador" => "bib0025"
              "etiqueta" => "5"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "High-Frequency jet ventilaton during resection of tracheal stenosis in a 14-year-old case"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:5 [
                            0 => "A&#46; Alagoz"
                            1 => "F&#46; Ulus"
                            2 => "H&#46; Sazak"
                            3 => "A&#46; Caudal"
                            4 => "E&#46; Savkilioglu"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "Pediatr Anesth"
                        "fecha" => "2008"
                        "volumen" => "18"
                        "paginaInicial" => "795"
                        "paginaFinal" => "796"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            5 => array:3 [
              "identificador" => "bib0030"
              "etiqueta" => "6"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "High-frequency jet ventilation in interventional bronchoscopy&#58; factors with predictive value on high-frequency jet ventilation complications"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "A&#46; Fern&#225;ndez-Bustamante"
                            1 => "V&#46; Ib&#225;&#241;ez"
                            2 => "J&#46;J&#46; Alfaro"
                            3 => "E&#46; De Miguel"
                            4 => "M&#46;J&#46; Germ&#225;n"
                            5 => "A&#46; May"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.jclinane.2005.12.011"
                      "Revista" => array:7 [
                        "tituloSerie" => "J Clin Anesth"
                        "fecha" => "2006"
                        "volumen" => "18"
                        "paginaInicial" => "349"
                        "paginaFinal" => "356"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/16905080"
                            "web" => "Medline"
                          ]
                        ]
                        "itemHostRev" => array:3 [
                          "pii" => "S0001731010004503"
                          "estado" => "S300"
                          "issn" => "00017310"
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            6 => array:3 [
              "identificador" => "bib0035"
              "etiqueta" => "7"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Reliable tidal volume estimates at the airway opening with an infant monitor during high-frecuency oscillatory ventilation"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:4 [
                            0 => "P&#46; Scalfaro"
                            1 => "J&#46; Pillow"
                            2 => "P&#46;D&#46; Sly"
                            3 => "Cotting J"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Crit Care Med"
                        "fecha" => "2001"
                        "volumen" => "29"
                        "paginaInicial" => "1925"
                        "paginaFinal" => "1930"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/11588453"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            7 => array:3 [
              "identificador" => "bib0040"
              "etiqueta" => "8"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Determinants of tidal volume during high frequency oscillation"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:4 [
                            0 => "K&#46;A&#46; Sedeek"
                            1 => "M&#46; Takeuchi"
                            2 => "K&#46; Suchodolsky"
                            3 => "R&#46;M&#46; Kacmarek"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1097/01.CCM.0000044504.43673.B0"
                      "Revista" => array:6 [
                        "tituloSerie" => "Crit Care Med"
                        "fecha" => "2003"
                        "volumen" => "31"
                        "paginaInicial" => "227"
                        "paginaFinal" => "231"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/12545020"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            8 => array:3 [
              "identificador" => "bib0045"
              "etiqueta" => "9"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Total and regional lung volume changes during high-frequency oscillatory ventilation &#40;HFOV&#41; of the normal lung"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "R&#46;B&#46; Easley"
                            1 => "C&#46;T&#46; Lancaster"
                            2 => "M&#46;K&#46; Fuld"
                            3 => "J&#46;W&#46; Custer"
                            4 => "D&#46;N&#46; Hager"
                            5 => "D&#46;W&#46; Kaczka"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1249/MSS.0000000000000663"
                      "Revista" => array:6 [
                        "tituloSerie" => "Respiratory Physiology &#38; Neurobiology"
                        "fecha" => "2009"
                        "volumen" => "165"
                        "paginaInicial" => "54"
                        "paginaFinal" => "60"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25785931"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            9 => array:3 [
              "identificador" => "bib0050"
              "etiqueta" => "10"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Four methods of measuring tidal volume during high-frecuency oscillatory ventilation"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "D&#46;N&#46; Hager"
                            1 => "M&#46; Fuld"
                            2 => "D&#46;W&#46; Kaczka"
                            3 => "J&#46;W&#46; Custer"
                            4 => "D&#46;N&#46; Hager"
                            5 => "D&#46;W&#46; Kaczka"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1097/01.CCM.0000201400.63304.41"
                      "Revista" => array:6 [
                        "tituloSerie" => "Crit Care Med"
                        "fecha" => "2006"
                        "volumen" => "34"
                        "paginaInicial" => "751"
                        "paginaFinal" => "757"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/16505661"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            10 => array:3 [
              "identificador" => "bib0055"
              "etiqueta" => "11"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "High frecuency oscillatory ventilation in pediatric patients"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:2 [
                            0 => "G&#46;P&#46; Priebe"
                            1 => "J&#46;H&#46; Arnold"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "Respir Care Clin North Am"
                        "fecha" => "2001"
                        "volumen" => "7"
                        "paginaInicial" => "633"
                        "paginaFinal" => "645"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            11 => array:3 [
              "identificador" => "bib0060"
              "etiqueta" => "12"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Ventilaci&#243;n de alta frecuencia"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:5 [
                            0 => "F&#46; Martin&#243;n-Torres"
                            1 => "I&#46; Ibarra"
                            2 => "F&#46; Fern&#225;ndez"
                            3 => "E&#46; Garc&#237;a"
                            4 => "J&#46;M&#46; Martin&#243;n"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "An Pediatr &#40;Barc&#41;"
                        "fecha" => "2003"
                        "volumen" => "59"
                        "paginaInicial" => "155"
                        "paginaFinal" => "180"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            12 => array:3 [
              "identificador" => "bib0065"
              "etiqueta" => "13"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Quantification of lung volume at different tidal volumes and positive end-expiration pressures in a porcine model by using retrospective respiratory gated 4D-Computed Tomography"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "J&#46; Ley-Zaporozhan"
                            1 => "S&#46; Ley"
                            2 => "R&#46; Unterhinninghofen"
                            3 => "O&#46; Weinheimer"
                            4 => "Y&#46;M&#46;E&#46; Saito"
                            5 => "H&#46;U&#46; Kauczor"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1097/RLI.0b013e318169000e"
                      "Revista" => array:6 [
                        "tituloSerie" => "Invest Radiol"
                        "fecha" => "2008"
                        "volumen" => "43"
                        "paginaInicial" => "461"
                        "paginaFinal" => "469"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/18496053"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            13 => array:3 [
              "identificador" => "bib0070"
              "etiqueta" => "14"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Tidal volume delivery during high-frequency oscillatory ventilation in adults with acute respiratory distress syndrome"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "D&#46; Hager"
                            1 => "E&#46; Fessler"
                            2 => "D&#46;W&#46; Kaczka"
                            3 => "C&#46;B&#46; Shanhoitz"
                            4 => "M&#46;K&#46; Fuld"
                            5 => "B&#46;A&#46; Simon"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1097/01.CCM.0000266586.04676.55"
                      "Revista" => array:6 [
                        "tituloSerie" => "Crit Care Med"
                        "fecha" => "2007"
                        "volumen" => "35"
                        "paginaInicial" => "1522"
                        "paginaFinal" => "1528"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/17440422"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            14 => array:3 [
              "identificador" => "bib0075"
              "etiqueta" => "15"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "In vitro performance characteristics of high-frequency oscillatory ventilators"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:4 [
                            0 => "J&#46; Pillow"
                            1 => "M&#46;H&#46; Wilkinson"
                            2 => "H&#46;L&#46; Neil"
                            3 => "C&#46;A&#46; Ramsden"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1164/ajrccm.164.6.2005008"
                      "Revista" => array:6 [
                        "tituloSerie" => "Am J Respir Crit Care Med"
                        "fecha" => "2001"
                        "volumen" => "164"
                        "paginaInicial" => "1019"
                        "paginaFinal" => "1024"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/11587990"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
          ]
        ]
      ]
    ]
  ]
  "idiomaDefecto" => "es"
  "url" => "/16954033/0000007600000001/v1_201304302006/S1695403311003687/v1_201304302006/es/main.assets"
  "Apartado" => array:4 [
    "identificador" => "14282"
    "tipo" => "SECCION"
    "es" => array:2 [
      "titulo" => "Originales"
      "idiomaDefecto" => true
    ]
    "idiomaDefecto" => "es"
  ]
  "PDF" => "https://static.elsevier.es/multimedia/16954033/0000007600000001/v1_201304302006/S1695403311003687/v1_201304302006/es/main.pdf?idApp=UINPBA00005H&text.app=https://analesdepediatria.org/"
  "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1695403311003687?idApp=UINPBA00005H"
]
Compartir
Información de la revista
Vol. 76. Núm. 1.
Páginas 11-15 (enero 2011)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
28668
Vol. 76. Núm. 1.
Páginas 11-15 (enero 2011)
Original
Acceso a texto completo
Medición del volumen corriente en ventilación de alta frecuencia
Measuring tidal volume during paediatric oscillatory and jet high-frequency ventilation
Visitas
28668
M.J. Solana, J. López-Herce
Autor para correspondencia
pielvi@hotmail.com

Autor para correspondencia.
, J. Urbano, S. Mencía, J. del Castillo, J.M. Bellón
Servicio de Cuidados Intensivos Pediátricos, Hospital General Universitario Gregorio Marañón, Universidad Complutense, Madrid, España
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (4)
Mostrar másMostrar menos
Resumen
Objetivo

Valorar si un espirómetro puede medir el volumen corriente en ventilación de alta frecuencia oscilatoria (VAFO) y por jet (VAFJ) y analizar el efecto de los cambios en los parámetros del respirador.

Métodos

Se realizó un estudio con pulmones de prueba pediátricos y en cerdos. Para la VAFO se utilizó el respirador Sensormedics 3100BR y para la VAFJ el respirador Paravent PateR. La medición del volumen corriente (VC) se realizó con un espirómetro D-Fend. Se realizaron cambios en la frecuencia, amplitud y presión media en la vía aérea (PMVA), registrándose los cambios en el VC y las presiones.

Resultados

El espirómetro midió el VC en los pulmones de prueba y en los cerdos, pero no pudo medir VC menores de 8ml, cuando la amplitud era mayor de 55cmH2O o la PMVA mayor de 30cmH2O. En la VAFO existió una correlación entre la amplitud y el VC y en la VAFJ entre la presión y el VC. En ambos respiradores existió una correlación negativa entre la frecuencia y el VC.

Conclusiones

El espirómetro D-Fend puede medir el volumen corriente durante la VAFO y la VAFJ, pero no es capaz de medir VC menores de 8 o cuando se utilizan amplitudes o presiones elevadas.

Palabras clave:
Ventilación de alta frecuencia
Ventilación de alta frecuencia por jet
Monitorización respiratoria
Espirómetro
Volumen corriente
Niños
Abstract
Objective

To ascertain whether a spirometer can measure tidal volume (TV) during high frequency oscillatory ventilation (HFOV) and high frequency jet ventilation (HFJV), and to analyse the effect of changes in ventilator settings.

Methods

The study was performed with paediatric porcine lung models submitted to HFOV with a Sensormedics 3100 ventilator and HFJV with a Paravent PateR ventilator connected to a D-Fend spirometer. Programmed frequency, amplitude, and mean airway pressure (MAP) were changed in the ventilator, and TV and pressures were recorded using the spirometer.

Results

The spirometer measured TV in the paediatric lung models and piglets, but could not measure TV less than 8ml, when the pressure amplitude was higher than 55cmH2O or the MAP was higher than 30cmH2O. With HFOV there was a correlation between amplitude and tidal volume, and a positive correlation between pressure and TV with HFJV. With both respirators there was a negative correlation between frequency and TV.

Conclusions

The D-Fend spirometer can measure tidal volume and pressure during HFOV and HFJV. However, it does not work with volumes lower than 8ml, and high amplitude or mean airway pressure.

Keywords:
High-frequency ventilation
High-frequency jet ventilation
Respiratory monitoring
Spirometer
Tidal volume
Paediatrics
Texto completo
Introducción

La ventilación de alta frecuencia (VAF) es una técnica de soporte respiratorio indicada para pacientes con insuficiencia respiratoria hipoxémica y/o hipercápnica refractaria a ventilación mecánica convencional1,2. Existen diferentes tipos de ventilación de alta frecuencia, siendo la ventilación de alta frecuencia oscilatoria (VAFO) la más utilizada3. El respirador Sensormedics 3100 (ViasysR) es el respirador de VAFO más utilizado en los niños con peso superior a los 2-3kg, ya que puede usarse en un rango amplio de pacientes. La ventilación de alta frecuencia por jet (VAFJ) se utiliza en pacientes sometidos a cirugía de la vía aérea y en neonatos prematuros con enfermedad de membrana hialina4,5.

Los respiradores de ventilación convencional miden el flujo, volumen y la presión mediante sensores colocados inmediatamente antes de su conexión al tubo endotraqueal. Uno de los mayores problemas de algunos respiradores de VAFO y VAFJ es que no pueden medir el VC. Este hecho unido a la imposibilidad de utilizar capnografía dificulta el control de la ventilación durante esta técnica. La ventilación solo puede ser monitorizada por la observación de la vibración y la medida de la PCO2 arterial o transcutánea6,7.

En la VAF se utilizan volúmenes corrientes bajos de 1 a 2ml/kg. Sin embargo, los cambios en los volúmenes corrientes producen importantes cambios en el intercambio gaseoso ya que el volumen minuto es dependiente de la frecuencia respiratoria por el volumen corriente elevado al cuadrado. Esta es la razón por la que la monitorización del VC es importante en la VAF. A pesar de ello, existen muy pocos estudios que hayan estudiado la capacidad de los espirómetros para medir el VC en niños o modelos animales pediátricos con VAFO8,9, y ninguno lo ha estudiado con la VAFJ.

El objetivo de este estudio ha sido estudiar si un espirómetro basado en el tubo de Pitot puede medir los volúmenes corrientes generados durante la VAFO y la VAFJ y analizar el efecto de la modificación de los distintos parámetros de la ventilación de alta frecuencia (amplitud, frecuencia y presión media) sobre el volumen corriente.

Material y métodos

El estudio se llevo a cabo en dos fases: inicialmente sobre simuladores de pulmón artificial pediátrico y posteriormente en un modelo animal infantil. El protocolo fue aprobado por el Comité hospitalario de Ética e Investigación.

Estudio in experimental in vitro. Se utilizaron dos pulmones artificiales, uno adulto-pediátrico (Adult/Pediatric Demonstration Lung, Ingmar MedicalR) y otro neonatal (Neonatal Demonstration Lung model, DragerR), conectados a un respirador de VAFO (Sensormedics 3100 B, (ViasysR) y a otro de VAFJ (Paravent PATe, Respiromed, Czech Republic). Entre ambos se colocó un espirómetro D-Fend (Datex-Ohmeda) que mide el volumen corriente inspirado (VCI), volumen corriente espirado (VCE), las presiones y flujos conectado a un módulo de función respiratoria de un monitor Datex Ohmeda S5 (General Electric). El espirómetro D-Fend calcula el volumen corriente basándose en el principio de Bernoulli según el cual la diferencia de presión que se produce entre los extremos del espirómetro produce una señal de voltaje que es proporcional al flujo. Este método ha sido validado para medir el VC en modelos adultos de VAFO10.

Modelo animal: el experimento se repitió en un modelo animal infantil (3 cerdos minipig de pesos entre 7,5 y 14kg). Durante el estudio se siguieron las normas internacionales para el cuidado de los animales de experimentación, recibiendo sedación con propofol, fentanilo y relajación con atracurio. Los cerdos fueron intubados con un tubo endotraqueal de diámetro interno 4,5mm y conectados mediante un espirómetro D-Fend a los respiradores. Se canalizaron la vena y arteria femorales para la administración de medicación y extracción de gasometrías.

Protocolo experimental: en la VAFO se utilizaron los siguientes parámetros: flujo 20 L/min, porcentaje de tiempo inspiratorio (%Ti) 33% y fracción inspirada de oxígeno (FiO2) 60%. Se realizaron mediciones cambiando la frecuencia respiratoria (FR) (6,7,9 y 10 herzios (respiraciones/segundo) (Hz), la amplitud (AMP) 20,25,30,35,40,45,50,55,60,65 y 70cmH2O) y la presión media en la vía aérea (PMVA) 15, 25 y 30cmH2O) en cada uno de los pulmones artificiales y en el cerdo.

Con la VAFJ se mantuvo una relación I/E constante de 1/2 y se realizaron mediciones cambiando la FR (40, 120 y 180Hz) y la presión (15,20,25 y 30cmH2O).

Se registraron los valores de VCI, VCE, presión pico inspiratoria (PIP), presión espiratoria final (PEEP) y PMVA. Todas las medidas se realizaron dos veces. Los experimentos se llevaron a cabo en todos los casos en las mismas condiciones de humedad, presión y temperatura.

Los resultados fueron analizados con el programa SPSS versión 16.0, utilizándose una prueba de correlación parcial para estudiar la correlación entre los parámetros

ResultadosVentilación de alta frecuencia oscilatoria

El espirómetro fue capaz de medir los volúmenes en el pulmón artificial pediátrico-adulto pero no en el pulmón de prueba neonatal. El espirómetro tampoco fue capaz de medir el volumen corriente con amplitudes elevadas entre los 55 y 65cmH2O ni con PMVA más altas de 30cmH2O. En los animales el espirómetro solo detectó un VC de 8ml o superior, y cuando la amplitud era igual o superior a 35cmH2O.

Tanto en los pulmones artificiales como en los animales el VCI y VCE aumentaron al aumentar la amplitud (fig. 1), existiendo una buena correlación, que fue independiente de la frecuencia y la PMVA programadas. Por el contrario, el VCI y VCE fueron disminuyendo al aumentar la frecuencia existiendo una correlación inversa estadísticamente significativa (fig. 2). También existió una buena correlación entre la PMVA programada y las presiones registradas por el espirómetro (r=0,960, p<0,001).

Figura 1.

Relación entre el volumen corriente inspiratorio (VCI) y la amplitud en VAFO en el pulmón artificial y en los animales. Existió una elevada correlación entre ambos parámetros (r=0,855, p<0,001 en cerdos y r=0,703 p=0,002 en el pulmón artificial).

(0.1MB).
Figura 2.

Relación entre el volumen corriente inspiratorio (VCI) y la frecuencia respiratoria en VAFO en el pulmón artificial y en los animales.

Existió una correlación negativa entre ambos parámetros (r=−0,772, p=0,02 en cerdos y r=−0,650, p=0,03 en el pulmón artificial).

(0.1MB).
Ventilación de alta frecuencia por jet

El espirómetro midió el VC durante la VAFJ en el pulmón adulto-pediátrico, pulmón neonatal y en los cerdos con todas las presiones y frecuencias programadas. En ambos modelos el VCI y VCE aumentaron con la presión y presentaron una buena correlación entre ambos, independientemente de la frecuencia y la presión programada (fig. 3). El VCI y VCE disminuyeron al aumentar la frecuencia, existiendo una correlación inversa estadísticamente significativa (fig. 4). Existió una buena correlación entre la presión programada y la medida por el espirómetro (r=0,970, p<0,001).

Figura 3.

Relación entre el volumen corriente inspiratorio (VCI) y el pico de presión en VAFJ en el pulmón artificial y en los animales.

Existió una elevada correlación entre ambos parámetros (r=0,928, p<0,001 en cerdos y r=0,772, p=0,03 en el pulmón artificial).

(0.08MB).
Figura 4.

Relación entre el volumen corriente inspiratorio (VCI) y la frecuencia respiratoria en VAFJ en el pulmón artificial y en los animales.

Existió una correlación negativa entre ambos parámetros (r=−0,924, p<0,001 en cerdos y r=−0,934, p<0,001 en el pulmón artificial).

(0.08MB).
Discusión

La VAFO es un tipo de ventilación mecánica que favorece el intercambio gaseoso mediante la utilización de volúmenes pequeños (entre 1-2ml/kg) y frecuencias suprafisiológicas (3-20 hertzios, ciclos/sg) protegiendo al pulmón de la pérdida del reclutamiento alveolar y la sobredistensión9,11.

Los dispositivos de VAFO generan ondas de presión de alta amplitud a nivel proximal que se van atenuando por la resistencia que ejerce el circuito, de manera que al alveolo solamente le llegan ondas de baja amplitud evitándose así el barotrauma12.

La VAFJ consigue el intercambio gaseoso por medio de un efecto Venturi, administrando pequeños pulsos de gas caliente a través de un inyector que está conectado al tubo endotraqueal del paciente11. La frecuencia respiratoria utilizada en la VAFJ es elevada pero significativamente inferior a la de la VAFO. En este respirador la programación de la amplitud se realiza indirectamente por medio de la presión. En este tipo de ventilación la espiración es pasiva.

Sin embargo, en algunos respiradores como el Sensor Medics 3100 no es posible monitorizar el volumen corriente entregado al paciente existiendo por tanto riesgo de hipo o hiperventilación.

El volumen corriente generado en la VAFO se ha tratado de estimar mediante neumotacógrafos, pero estos requieren múltiples calibraciones que dependen de la frecuencia oscilatoria, la composición del gas, la amplitud, la temperatura y la humedad10. Por esta razón, se han desarrollado nuevos sistemas como la tomografía computarizada13, el anemómetro10,14, los ultrasonidos o el tubo de Pitot10. En este último método se basa el espirómetro que hemos empleado en nuestro estudio. No existen estudios previos que hayan medido el VC generado en la VAFJ.

En nuestro estudio hemos demostrado que el espirómetro D-Fend puede monitorizar el volumen corriente durante la VAFO y el VAFJ en modelos pediátricos en determinadas condiciones.

Estudios in vitro7,10,15 e in vivo con animales8,9,13 han demostrado el efecto de la amplitud y la frecuencia sobre el volumen corriente en la VAFO. Nuestros resultados son similares, ya que el VC aumentó con el incremento de la amplitud y disminuyó con el incremento de la frecuencia tanto en los pulmones artificiales como en los animales. Hay que tener en cuenta que la fórmula del volumen minuto es diferente en la ventilación de alta frecuencia y en la ventilación convencional, y que en la VAF los incrementos de FR disminuyen el VC y secundariamente el volumen minuto.

Nuestros resultados también muestran que en la VAFJ el VC aumenta con la presión, ya que es el equivalente de la amplitud en este tipo de ventilación, y disminuye con la frecuencia.

Por otra parte, la elevada correlación entre la PMVA programada y las presiones medidas por el espirómetro sugieren que el espirómetro D-Fend puede servir para monitorizar las presiones generadas durante la VAFO y la VAFJ.

El estudio tiene algunas limitaciones. El espirómetro no fue capaz de medir el VC en el pulmón neonatal probablemente por su incapacidad de medir VC bajos. Esta probablemente es la razón por la que tampoco logró medir el VC cuando se utilizaron amplitudes menores de 35cmH2O en los animales. Por otra parte, las especificaciones del monitor establecen que el mínimo VC detectado es de 15ml. Sin embargo, en nuestros experimentos logró medir VC a partir de 8ml. Este hecho limita la utilización de este monitor en los neonatos y los lactantes de bajo peso. Son necesarios estudios que confirmen nuestros resultados en niños de diferentes edades y pesos.

Concluimos que el espirómetro D-Fend puede medir el volumen corriente durante la VAFO y la VAFJ. Sin embargo no es capaz de medir VC menores de 8 o cuando se utilizan amplitudes o presiones elevadas.

Financiación

El estudio ha sido realizado con la ayuda de la Red de Salud Materno Infantil y del Desarrollo SAMID RD08/0072 del Instituto Carlos III del VI programa marco nacional 2008-2011.

Conflicto de intereses

Los autores declaran no tener ningún conflicto de intereses.

Bibliografía
[1]
A. Donoso, J. León, G. Rojas, C. Valverde, M. Escobar, M. Ramírez, et al.
Uso de ventilación de alta frecuencia oscilatoria en pacientes pediátricos.
Rev Chil Pediatr, 73 (2002), pp. 461-470
[2]
A. Donoso, P. Cruces, J. León, M. Ramírez, J. Camacho.
Ventilación de alta frecuencia oscilatoria en pacientes pediátricos.
Rev Chil Enferm Respir, 22 (2006), pp. 21-30
[3]
A. Bancalari.
Ventilación de alta frecuencia en el recién nacido: Un soporte respiratorio necesario.
Rev Chil Pediatr, 74 (2003), pp. 475-486
[4]
V.H. Joshi, T. Bhuta.
Rescue high frequency jet ventilation versus conventional ventilation for severe pulmonary dysfunction in preterm infants.
Cochrane Database Syst Rev, 25 (2006), pp. CD000437
[5]
A. Alagoz, F. Ulus, H. Sazak, A. Caudal, E. Savkilioglu.
High-Frequency jet ventilaton during resection of tracheal stenosis in a 14-year-old case.
Pediatr Anesth, 18 (2008), pp. 795-796
[6]
A. Fernández-Bustamante, V. Ibáñez, J.J. Alfaro, E. De Miguel, M.J. Germán, A. May, et al.
High-frequency jet ventilation in interventional bronchoscopy: factors with predictive value on high-frequency jet ventilation complications.
[7]
P. Scalfaro, J. Pillow, P.D. Sly, Cotting J.
Reliable tidal volume estimates at the airway opening with an infant monitor during high-frecuency oscillatory ventilation.
Crit Care Med, 29 (2001), pp. 1925-1930
[8]
K.A. Sedeek, M. Takeuchi, K. Suchodolsky, R.M. Kacmarek.
Determinants of tidal volume during high frequency oscillation.
Crit Care Med, 31 (2003), pp. 227-231
[9]
R.B. Easley, C.T. Lancaster, M.K. Fuld, J.W. Custer, D.N. Hager, D.W. Kaczka, et al.
Total and regional lung volume changes during high-frequency oscillatory ventilation (HFOV) of the normal lung.
Respiratory Physiology & Neurobiology, 165 (2009), pp. 54-60
[10]
D.N. Hager, M. Fuld, D.W. Kaczka, J.W. Custer, D.N. Hager, D.W. Kaczka, et al.
Four methods of measuring tidal volume during high-frecuency oscillatory ventilation.
Crit Care Med, 34 (2006), pp. 751-757
[11]
G.P. Priebe, J.H. Arnold.
High frecuency oscillatory ventilation in pediatric patients.
Respir Care Clin North Am, 7 (2001), pp. 633-645
[12]
F. Martinón-Torres, I. Ibarra, F. Fernández, E. García, J.M. Martinón.
Ventilación de alta frecuencia.
An Pediatr (Barc), 59 (2003), pp. 155-180
[13]
J. Ley-Zaporozhan, S. Ley, R. Unterhinninghofen, O. Weinheimer, Y.M.E. Saito, H.U. Kauczor, et al.
Quantification of lung volume at different tidal volumes and positive end-expiration pressures in a porcine model by using retrospective respiratory gated 4D-Computed Tomography.
Invest Radiol, 43 (2008), pp. 461-469
[14]
D. Hager, E. Fessler, D.W. Kaczka, C.B. Shanhoitz, M.K. Fuld, B.A. Simon, et al.
Tidal volume delivery during high-frequency oscillatory ventilation in adults with acute respiratory distress syndrome.
Crit Care Med, 35 (2007), pp. 1522-1528
[15]
J. Pillow, M.H. Wilkinson, H.L. Neil, C.A. Ramsden.
In vitro performance characteristics of high-frequency oscillatory ventilators.
Am J Respir Crit Care Med, 164 (2001), pp. 1019-1024
Copyright © 2011. Asociación Española de Pediatría
Descargar PDF
Idiomas
Anales de Pediatría
Opciones de artículo
Herramientas
es en

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?