array:23 [
  "pii" => "S1695403309006894"
  "issn" => "16954033"
  "doi" => "10.1016/j.anpedi.2009.10.021"
  "estado" => "S300"
  "fechaPublicacion" => "2010-03-01"
  "aid" => "362"
  "copyright" => "Asociación Española de Pediatría"
  "copyrightAnyo" => "2009"
  "documento" => "article"
  "crossmark" => 0
  "subdocumento" => "fla"
  "cita" => "An Pediatr (Barc). 2010;72:165-71"
  "abierto" => array:3 [
    "ES" => false
    "ES2" => false
    "LATM" => false
  ]
  "gratuito" => false
  "lecturas" => array:2 [
    "total" => 6066
    "formatos" => array:3 [
      "EPUB" => 108
      "HTML" => 4374
      "PDF" => 1584
    ]
  ]
  "itemSiguiente" => array:18 [
    "pii" => "S1695403309006833"
    "issn" => "16954033"
    "doi" => "10.1016/j.anpedi.2009.11.012"
    "estado" => "S300"
    "fechaPublicacion" => "2010-03-01"
    "aid" => "356"
    "copyright" => "Asociación Española de Pediatría"
    "documento" => "article"
    "crossmark" => 0
    "subdocumento" => "fla"
    "cita" => "An Pediatr (Barc). 2010;72:172-8"
    "abierto" => array:3 [
      "ES" => false
      "ES2" => false
      "LATM" => false
    ]
    "gratuito" => false
    "lecturas" => array:2 [
      "total" => 6197
      "formatos" => array:3 [
        "EPUB" => 98
        "HTML" => 5210
        "PDF" => 889
      ]
    ]
    "es" => array:13 [
      "idiomaDefecto" => true
      "cabecera" => "<span class="elsevierStyleTextfn">Original</span>"
      "titulo" => "Hospitalizaciones por <span class="elsevierStyleItalic">Bordetella pertussis&#58;</span> experiencia del Hospital del Ni&#241;o de Panam&#225;&#44; periodo 2001<span class="elsevierStyleHsp" style=""></span>&#8211;<span class="elsevierStyleHsp" style=""></span>2008"
      "tienePdf" => "es"
      "tieneTextoCompleto" => "es"
      "tieneResumen" => array:2 [
        0 => "es"
        1 => "en"
      ]
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "172"
          "paginaFinal" => "178"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "en" => array:1 [
          "titulo" => "Hospital admissions due to whooping cough&#58; experience of the del ni&#241;o hospital in Panama&#46; Period 2001<span class="elsevierStyleHsp" style=""></span>&#8211;<span class="elsevierStyleHsp" style=""></span>2008"
        ]
      ]
      "contieneResumen" => array:2 [
        "es" => true
        "en" => true
      ]
      "contieneTextoCompleto" => array:1 [
        "es" => true
      ]
      "contienePdf" => array:1 [
        "es" => true
      ]
      "resumenGrafico" => array:2 [
        "original" => 0
        "multimedia" => array:7 [
          "identificador" => "fig1"
          "etiqueta" => "Figura 1"
          "tipo" => "MULTIMEDIAFIGURA"
          "mostrarFloat" => true
          "mostrarDisplay" => false
          "figura" => array:1 [
            0 => array:4 [
              "imagen" => "gr1.jpeg"
              "Alto" => 794
              "Ancho" => 1631
              "Tamanyo" => 123733
            ]
          ]
          "descripcion" => array:1 [
            "es" => "<p class="elsevierStyleSimplePara elsevierViewall">Tasa de hospitalizaci&#243;n de casos confirmados de enfermedad por <span class="elsevierStyleItalic">B&#46; pertussis</span> en el Hospital del Ni&#241;o 2001<span class="elsevierStyleHsp" style=""></span>&#8211;<span class="elsevierStyleHsp" style=""></span>2008&#46;</p>"
          ]
        ]
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "J&#46; Nieto Guevara, K&#46; Luciani, A&#46; Montesdeoca Meli&#225;n, M&#46; Mateos Dur&#225;n, D&#46; Estripeaut"
          "autores" => array:5 [
            0 => array:2 [
              "nombre" => "J&#46;"
              "apellidos" => "Nieto Guevara"
            ]
            1 => array:2 [
              "nombre" => "K&#46;"
              "apellidos" => "Luciani"
            ]
            2 => array:2 [
              "nombre" => "A&#46;"
              "apellidos" => "Montesdeoca Meli&#225;n"
            ]
            3 => array:2 [
              "nombre" => "M&#46;"
              "apellidos" => "Mateos Dur&#225;n"
            ]
            4 => array:2 [
              "nombre" => "D&#46;"
              "apellidos" => "Estripeaut"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "es"
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1695403309006833?idApp=UINPBA00005H"
    "url" => "/16954033/0000007200000003/v2_201308271700/S1695403309006833/v2_201308271700/es/main.assets"
  ]
  "itemAnterior" => array:18 [
    "pii" => "S169540330900695X"
    "issn" => "16954033"
    "doi" => "10.1016/j.anpedi.2009.12.002"
    "estado" => "S300"
    "fechaPublicacion" => "2010-03-01"
    "aid" => "368"
    "copyright" => "Asociaci&#243;n Espa&#241;ola de Pediatr&#237;a"
    "documento" => "article"
    "crossmark" => 0
    "subdocumento" => "sco"
    "cita" => "An Pediatr &#40;Barc&#41;. 2010;72:163-4"
    "abierto" => array:3 [
      "ES" => false
      "ES2" => false
      "LATM" => false
    ]
    "gratuito" => false
    "lecturas" => array:2 [
      "total" => 3147
      "formatos" => array:3 [
        "EPUB" => 67
        "HTML" => 2676
        "PDF" => 404
      ]
    ]
    "es" => array:10 [
      "idiomaDefecto" => true
      "cabecera" => "<span class="elsevierStyleTextfn">Editorial</span>"
      "titulo" => "En defensa de la Pediatr&#237;a"
      "tienePdf" => "es"
      "tieneTextoCompleto" => "es"
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "163"
          "paginaFinal" => "164"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "en" => array:1 [
          "titulo" => "In defence of paediatrics"
        ]
      ]
      "contieneTextoCompleto" => array:1 [
        "es" => true
      ]
      "contienePdf" => array:1 [
        "es" => true
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "M&#46; Cruz Hern&#225;ndez"
          "autores" => array:1 [
            0 => array:2 [
              "nombre" => "M&#46;"
              "apellidos" => "Cruz Hern&#225;ndez"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "es"
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S169540330900695X?idApp=UINPBA00005H"
    "url" => "/16954033/0000007200000003/v2_201308271700/S169540330900695X/v2_201308271700/es/main.assets"
  ]
  "es" => array:20 [
    "idiomaDefecto" => true
    "cabecera" => "<span class="elsevierStyleTextfn">Original</span>"
    "titulo" => "Validaci&#243;n de la medici&#243;n transcut&#225;nea de la presi&#243;n parcial de di&#243;xido de carbono en el paciente cr&#237;tico pedi&#225;trico"
    "tieneTextoCompleto" => true
    "paginas" => array:1 [
      0 => array:2 [
        "paginaInicial" => "165"
        "paginaFinal" => "171"
      ]
    ]
    "autores" => array:1 [
      0 => array:4 [
        "autoresLista" => "S&#46; Fern&#225;ndez de Miguel, M&#46; Gaboli, R&#46; Gonz&#225;lez-Celador, P&#46; G&#243;mez de Quero, V&#46; Murga Herrero, J&#46;M&#46; S&#225;nchez Granados, R&#46; Payo P&#233;rez"
        "autores" => array:7 [
          0 => array:4 [
            "nombre" => "S&#46;"
            "apellidos" => "Fern&#225;ndez de Miguel"
            "email" => array:1 [
              0 => "sira007&#64;hotmail&#46;com"
            ]
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">¿</span>"
                "identificador" => "cor1"
              ]
            ]
          ]
          1 => array:2 [
            "nombre" => "M&#46;"
            "apellidos" => "Gaboli"
          ]
          2 => array:2 [
            "nombre" => "R&#46;"
            "apellidos" => "Gonz&#225;lez-Celador"
          ]
          3 => array:2 [
            "nombre" => "P&#46;"
            "apellidos" => "G&#243;mez de Quero"
          ]
          4 => array:2 [
            "nombre" => "V&#46;"
            "apellidos" => "Murga Herrero"
          ]
          5 => array:2 [
            "nombre" => "J&#46;M&#46;"
            "apellidos" => "S&#225;nchez Granados"
          ]
          6 => array:2 [
            "nombre" => "R&#46;"
            "apellidos" => "Payo P&#233;rez"
          ]
        ]
        "afiliaciones" => array:1 [
          0 => array:1 [
            "entidad" => "Unidad de Cr&#237;ticos y Urgencias Pedi&#225;tricas&#44; Hospital Universitario de Salamanca&#44; Salamanca&#44; Espa&#241;a"
          ]
        ]
        "correspondencia" => array:1 [
          0 => array:3 [
            "identificador" => "cor1"
            "etiqueta" => "&#8270;"
            "correspondencia" => "Autor para correspondencia&#46;"
          ]
        ]
      ]
    ]
    "titulosAlternativos" => array:1 [
      "en" => array:1 [
        "titulo" => "Validation of the transcutaneous carbon dioxide tension measurements in critical paediatric patients"
      ]
    ]
    "resumenGrafico" => array:2 [
      "original" => 0
      "multimedia" => array:7 [
        "identificador" => "fig1"
        "etiqueta" => "Figura 1"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr1.jpeg"
            "Alto" => 1519
            "Ancho" => 1637
            "Tamanyo" => 84281
          ]
        ]
        "descripcion" => array:1 [
          "es" => "<p class="elsevierStyleSimplePara elsevierViewall">Correlaci&#243;n entre los valores de presi&#243;n trancut&#225;nea de di&#243;xido de carbono &#40;PtCO<span class="elsevierStyleInf">2</span>&#41; y presi&#243;n arterial de di&#243;xido de carbono &#40;PaCO<span class="elsevierStyleInf">2</span>&#41;&#46; r<span class="elsevierStyleSup">2</span><span class="elsevierStyleHsp" style=""></span>&#61;0&#44;87 &#40;p<span class="elsevierStyleHsp" style=""></span>&#60;<span class="elsevierStyleHsp" style=""></span>0&#46;001&#41;</p>"
        ]
      ]
    ]
    "textoCompleto" => "<span class="elsevierStyleSections"><span class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle">Introducci&#243;n</span><p class="elsevierStylePara elsevierViewall">La posibilidad de monitorizar de forma continua la presi&#243;n parcial de ox&#237;geno y la presi&#243;n arterial de di&#243;xido de carbono &#40;PaCO<span class="elsevierStyleInf">2</span>&#41; usando electrodos t&#233;rmicos sobre la piel fue descubierta en los a&#241;os setenta del siglo pasado&#46; La pulsioximetr&#237;a ha tenido una amplia difusi&#243;n y disponemos de sistemas transcut&#225;neos fiables con correlaci&#243;n precisa con la saturaci&#243;n arterial de ox&#237;geno&#46; Los sistemas de monitorizaci&#243;n transcut&#225;nea de di&#243;xido de carbono presentaban problemas t&#233;cnicos que limitaron su uso<a class="elsevierStyleCrossRefs" href="#bib1"><span class="elsevierStyleSup">1&#8211;3</span></a>&#46;</p><p class="elsevierStylePara elsevierViewall">Para un correcto control de la ventilaci&#243;n lo &#243;ptimo es monitorizar la presi&#243;n de di&#243;xido de carbono &#40;PCO<span class="elsevierStyleInf">2</span>&#41;<a class="elsevierStyleCrossRefs" href="#bib4"><span class="elsevierStyleSup">4&#44;5</span></a>&#46; El &#171;gold standard&#187; contin&#250;a siendo la PaCO<span class="elsevierStyleInf">2</span>&#46; Esta determinaci&#243;n&#44; mediante punci&#243;n o canalizaci&#243;n arterial&#44; resulta invasiva&#44; dolorosa y no aporta informaci&#243;n en tiempo real&#59; es discontinua&#44; supone un coste elevado y no est&#225; exenta de complicaciones&#46; La posibilidad de disponer de un m&#233;todo no invasivo&#44; continuo y fiable de medir o estimar la PaCO<span class="elsevierStyleInf">2</span> resultar&#237;a de gran ayuda en muchas situaciones cl&#237;nicas&#46; En la actualidad se utilizan dos t&#233;cnicas&#58;<ul class="elsevierStyleList"><li class="elsevierStyleListItem"><span class="elsevierStyleLabel">&#8226;</span><p class="elsevierStylePara elsevierViewall">monitorizaci&#243;n del CO<span class="elsevierStyleInf">2</span> espirado &#40;PetCO<span class="elsevierStyleInf">2</span>&#41; mediante capnograf&#237;a&#58; presenta resultados irregulares con mala correlaci&#243;n en pacientes con patolog&#237;a del par&#233;nquima pulmonar&#44; alteraci&#243;n de la relaci&#243;n ventilaci&#243;n-perfusi&#243;n&#44; en ventilaci&#243;n unipulmonar&#44; obstrucci&#243;n de v&#237;a a&#233;rea y en paciente hemodinamicamente inestable&#46; Adem&#225;s la perdida de aire espirado como en presencia de fugas y en la ventilaci&#243;n no invasiva limita sensiblemente esta t&#233;cnica&#46; Tambi&#233;n se han descrito variaciones en funci&#243;n de la posici&#243;n del paciente<a class="elsevierStyleCrossRefs" href="#bib6"><span class="elsevierStyleSup">6&#8211;8</span></a>&#46;</p></li><li class="elsevierStyleListItem"><span class="elsevierStyleLabel">&#8226;</span><p class="elsevierStylePara elsevierViewall">medici&#243;n de la presi&#243;n transcut&#225;nea de CO<span class="elsevierStyleInf">2</span> &#40;PtCO<span class="elsevierStyleInf">2</span>&#41;&#58; se basa en la alta solubilidad y difusi&#243;n del CO<span class="elsevierStyleInf">2</span> a trav&#233;s de la piel&#46; Los sistemas actuales utilizan el principio de Severinghaus<span class="elsevierStyleSup">1</span> &#40;electrodo sensible a los cambios de pH inducidos por el CO<span class="elsevierStyleInf">2</span> en una soluci&#243;n acuosa a&#241;adiendo NaHCO<span class="elsevierStyleInf">2</span>&#41;&#46; La medici&#243;n se realiza colocando sobre la piel un electrodo que calienta hasta una temperatura de 42<span class="elsevierStyleHsp" style=""></span>&#176;C produciendo arteriolizaci&#243;n de la sangre<a class="elsevierStyleCrossRef" href="#bib3"><span class="elsevierStyleSup">3</span></a>&#46;</p></li></ul></p><p class="elsevierStylePara elsevierViewall">En el &#225;mbito pedi&#225;trico los sistemas de monitorizaci&#243;n de PtCO<span class="elsevierStyleInf">2</span> siguen presentando serias limitaciones&#46; Entre ellas destacan&#58; quemaduras en la piel por la temperatura de los electrodos&#44; erosiones cut&#225;neas por alta adhesividad&#44; intervalos de calibraci&#243;n y estabilizaci&#243;n largos&#44; necesidad de cambiar electrodos de lugar cada 2&#8211;4<span class="elsevierStyleHsp" style=""></span>h y lectura poco fiable en situaci&#243;n de acidosis&#44; vasoconstricci&#243;n o hipotensi&#243;n<a class="elsevierStyleCrossRefs" href="#bib1"><span class="elsevierStyleSup">1&#44;2</span></a>&#46;</p><p class="elsevierStylePara elsevierViewall">Existe actualmente un sistema de monitorizaci&#243;n digital&#44; el analizador de PtCO<span class="elsevierStyleInf">2</span> SenTec Digital Monitor &#40;distribuido en Espa&#241;a por Bioline Supply&#41; que por medio de un sensor digital &#40;V-Sign sensor&#41; permite monitorizar de forma continua la PtCO<span class="elsevierStyleInf">2</span>&#44; aportando adem&#225;s informaci&#243;n sobre la saturaci&#243;n perif&#233;rica de ox&#237;geno &#40;SpO<span class="elsevierStyleInf">2</span>&#41; y la frecuencia cardiaca&#46; Se aplica en el l&#243;bulo de la oreja mediante una pinza&#46; Su utilizaci&#243;n es sencilla&#44; c&#243;moda&#44; y su tolerancia buena&#46; La experiencia con este monitor y sensor en adultos ha demostrado una buena correlaci&#243;n entre la PaCO<span class="elsevierStyleInf">2</span> y la PtCO<span class="elsevierStyleInf">2</span>&#44; tanto en adultos sanos<a class="elsevierStyleCrossRef" href="#bib4"><span class="elsevierStyleSup">4</span></a> como en adultos con patolog&#237;a respiratoria<a class="elsevierStyleCrossRefs" href="#bib5"><span class="elsevierStyleSup">5&#44;7&#44;9&#44;10</span></a>&#46; Adem&#225;s se ha utilizado en adultos durante diferentes procedimientos que requer&#237;an sedoanalgesia&#44; como broncoscopia<a class="elsevierStyleCrossRef" href="#bib11"><span class="elsevierStyleSup">11</span></a>&#44; colonoscopia<a class="elsevierStyleCrossRef" href="#bib12"><span class="elsevierStyleSup">12</span></a>&#44; y en ventilaci&#243;n unipulmonar durante toracoscopia<a class="elsevierStyleCrossRef" href="#bib6"><span class="elsevierStyleSup">6</span></a>&#46;Por &#250;ltimo hay datos relativos a su utilizaci&#243;n durante la ventilaci&#243;n no invasiva<a class="elsevierStyleCrossRef" href="#bib8"><span class="elsevierStyleSup">8</span></a> o durante el test de apnea en muerte cerebral<a class="elsevierStyleCrossRef" href="#bib13"><span class="elsevierStyleSup">13</span></a>&#46;</p><p class="elsevierStylePara elsevierViewall">En pacientes pedi&#225;tricos existen escasas publicaciones con este monitor y sensor<a class="elsevierStyleCrossRefs" href="#bib14"><span class="elsevierStyleSup">14&#44;15</span></a>&#46; El trabajo m&#225;s extenso se refiere a pacientes mayores de un a&#241;o sin ventilaci&#243;n mec&#225;nica<a class="elsevierStyleCrossRef" href="#bib15"><span class="elsevierStyleSup">15</span></a>&#46; Sin embargo&#44; en ni&#241;os peque&#241;os &#40;especialmente en lactantes y neonatos&#41; la colocaci&#243;n del sensor mediante pinza en el l&#243;bulo auricular presenta problemas por la escasa superficie cut&#225;nea para adaptar el sensor&#46;</p><p class="elsevierStylePara elsevierViewall">Recientemente se ha comercializado un anillo espec&#237;fico para la aplicaci&#243;n del sensor en pacientes pedi&#225;tricos &#40;V-Sign sensor MDB 04&#46;04&#46;02&#44; distribuido en Espa&#241;a por Bioline Supply&#41;&#46; Dicho anillo puede usarse en todas las edades en diferentes localizaciones cut&#225;neas sobre prominencia &#243;sea &#40;clavicular&#44; esternal&#44; frontal&#44; etc&#46;&#41; siendo por lo tanto m&#225;s adaptable al paciente pedi&#225;trico&#46; Permite la monitorizaci&#243;n de la PtCO<span class="elsevierStyleInf">2</span> calentando la piel solamente hasta 40<span class="elsevierStyleHsp" style=""></span>&#176;C&#46; A&#250;n no registra la SpO<span class="elsevierStyleInf">2</span> ni la frecuencia cardiaca en estas condiciones&#46; Hasta la fecha&#44; seg&#250;n conocimiento de los autores&#44; revisada la literatura&#44; no se han publicado estudios sobre la fiabilidad y seguridad del sistema&#44; ni sobre sus posibles inconvenientes t&#233;cnicos&#46; El sistema se calibra de forma autom&#225;tica por medio de una concentraci&#243;n conocida de CO<span class="elsevierStyleInf">2</span>&#59; este proceso requiere pocos minutos&#46; Se puede monitorizar la PtCO<span class="elsevierStyleInf">2</span> durante 8<span class="elsevierStyleHsp" style=""></span>h seguidas sin necesidad de repetir la calibraci&#243;n&#46; La membrana del sensor se debe cambiar cada 28 d&#237;as seg&#250;n instrucciones del fabricante&#46; Permite adem&#225;s el registro completo del estudio para su an&#225;lisis posterior&#44; por medio de un software espec&#237;fico en un ordenador&#46;</p><p class="elsevierStylePara elsevierViewall">El objetivo principal de este estudio consiste en valorar la fiabilidad de la medici&#243;n de la PtCO<span class="elsevierStyleInf">2</span> respecto a la medici&#243;n directa de la PaCO<span class="elsevierStyleInf">2</span>&#46; Se realiza en una cohorte de pacientes pedi&#225;tricos ingresados en una unidad de cuidados intensivos&#46; Se pretende establecer la correlaci&#243;n&#44; la asociaci&#243;n y el grado de acuerdo entre la PtCO<span class="elsevierStyleInf">2</span> y la PaCO<span class="elsevierStyleInf">2</span>&#44; utilizando el anillo para la aplicaci&#243;n del sensor dise&#241;ado especificamente para pacientes pedi&#225;tricos&#46; Se analiza adem&#225;s si las diferencias individuales entre la PtCO<span class="elsevierStyleInf">2</span> y PaCO<span class="elsevierStyleInf">2</span> se mantienen constantes&#46;</p><p class="elsevierStylePara elsevierViewall">Como objetivo secundario se plantea verificar si la correlaci&#243;n entre PtCO<span class="elsevierStyleInf">2</span> y PaCO<span class="elsevierStyleInf">2</span> y la diferencia entre las dos medidas son iguales en diferentes situaciones cl&#237;nicas y t&#233;cnicas &#40;localizaci&#243;n del sensor&#44; tiempo desde calibraci&#243;n&#44; etc&#46;&#41;&#46;</p><p class="elsevierStylePara elsevierViewall">Por &#250;ltimo se registran posibles efectos secundarios y problemas t&#233;cnicos derivados de la utilizaci&#243;n del sensor aplicado con anillo&#46;</p></span><span class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle">Material y m&#233;todos</span><p class="elsevierStylePara elsevierViewall">El estudio se dise&#241;&#243; como anal&#237;tico&#44; observacional&#44; longitudinal y prospectivo de cohorte din&#225;mica&#46;</p><p class="elsevierStylePara elsevierViewall">La muestra la constituyeron los pacientes ingresados en la unidad de cuidados intensivos pedi&#225;tricos entre octubre de 2008 y febrero de 2009&#46; Se tom&#243; como criterio de inclusi&#243;n la necesidad de cateterizaci&#243;n arterial debido a la situaci&#243;n cl&#237;nica del paciente&#46; Se obtuvo consentimiento informado de los padres o tutores y las correspondientes autorizaciones por parte del comit&#233; &#233;tico y de la unidad de investigaci&#243;n del centro donde se realiz&#243; el estudio&#46;</p><p class="elsevierStylePara elsevierViewall">En cada paciente&#44; cuando su situaci&#243;n cl&#237;nica precisaba la realizaci&#243;n de una gasometr&#237;a arterial&#44; se realizaban dos determinaciones de PCO<span class="elsevierStyleInf">2</span>&#58; una transcut&#225;nea y otra arterial&#46; Las mediciones de PtCO<span class="elsevierStyleInf">2</span> se realizaron con el monitor digital SenTec &#40;versi&#243;n SMB 06&#46;20&#46;02&#44; Therwill&#44; Suiza&#41; y un sensor especifico aplicado mediante un anillo &#40;sensor V-sign&#44; versi&#243;n MDB 04&#46;04&#46;02&#41;&#46; Dicho sensor calienta la piel hasta 40<span class="elsevierStyleHsp" style=""></span>&#176;C para lograr arterializaci&#243;n de la sangre&#46; Se posiciona a nivel cut&#225;neo sobre prominencia &#243;sea tras a&#241;adir una gota de gel difusor&#46; Previo a su aplicaci&#243;n el sensor se calibr&#243; seg&#250;n las instrucciones del fabricante&#46; Tras su colocaci&#243;n se esper&#243; un tiempo de 10&#8211;15<span class="elsevierStyleHsp" style=""></span>min hasta la correcta estabilizaci&#243;n del valor de PtCO<span class="elsevierStyleInf">2</span>&#46; Las mediciones de PaCO<span class="elsevierStyleInf">2</span> se realizaron en un analizador de gases GEM Premium 3&#46;000 &#40;Instrumentation Laboratory&#41;&#46; Para evitar sesgos se realizaron sesiones de adiestramiento para la utilizaci&#243;n del equipo dirigidas a todo el personal de la unidad&#46;</p><p class="elsevierStylePara elsevierViewall">Adem&#225;s de las presiones de CO<span class="elsevierStyleInf">2</span>&#44; en cada paciente se recogieron las siguientes variables independientes&#58; edad&#44; sexo&#44; peso&#44; talla&#44; superficie corporal y diagn&#243;sticos al ingreso&#46; As&#237; mismo con cada determinaci&#243;n se anotaron los siguientes datos&#58; frecuencia cardiaca&#44; tensi&#243;n arterial&#44; tipo y dosis de f&#225;rmacos inotr&#243;picos&#59; saturaci&#243;n perif&#233;rica de ox&#237;geno&#59; tipo&#44; modalidad y par&#225;metros de asistencia respiratoria&#59; saturaci&#243;n arterial de ox&#237;geno&#44; pH&#44; concentraci&#243;n de &#225;cido l&#225;ctico y de bicarbonato&#44; exceso de bases&#44; PaO<span class="elsevierStyleInf">2</span>&#59; localizaci&#243;n del sensor&#44; tiempo transcurrido desde la &#250;ltima calibraci&#243;n del sensor y desde el &#250;timo cambio de membrana&#46;</p><p class="elsevierStylePara elsevierViewall">Para el manejo de los datos se cre&#243; una base de datos con el programa Access de Microsoft y para el an&#225;lisis se utiliz&#243; el programa SPSS versi&#243;n 15&#46;0 para Window&#46;</p><p class="elsevierStylePara elsevierViewall">En el an&#225;lisis de los datos se utiliz&#243; la regresi&#243;n lineal&#44; calculando la significaci&#243;n estad&#237;stica de la asociaci&#243;n entre determinaciones mediante el test F de Snedecor y el coeficiente de correlaci&#243;n r<span class="elsevierStyleSup">2</span> de Pearson&#46; Con el fin de evitar las limitaciones de este coeficiente&#44; se calcul&#243; tambi&#233;n el coeficiente de correlaci&#243;n intraclase&#46; Cuando la correlaci&#243;n fue significativa&#44; se obtuvo la ecuaci&#243;n de regresi&#243;n correspondiente&#46; El grado de acuerdo entre las mediciones pareadas se estudi&#243; con el m&#233;todo de Bland y Altman<a class="elsevierStyleCrossRef" href="#bib16"><span class="elsevierStyleSup">16</span></a>&#46;</p><p class="elsevierStylePara elsevierViewall">La consistencia de los resultados se comprob&#243; analizando el comportamiento de la PtCO<span class="elsevierStyleInf">2</span> al variar la PaCO<span class="elsevierStyleInf">2</span> entre determinaciones&#46; Para ello se realiz&#243; el ANOVA entre las dos primeras medidas de cada paciente as&#237; como la correlaci&#243;n entre ellas&#46;</p><p class="elsevierStylePara elsevierViewall">Con el fin de detectar factores que pudieran asociarse o influir en la variaci&#243;n de la correlaci&#243;n PaCO<span class="elsevierStyleInf">2</span>-PtCO<span class="elsevierStyleInf">2</span>&#44; y para validar el sistema de medici&#243;n en diferentes situaciones cl&#237;nicas&#44; se llev&#243; a cabo un an&#225;lisis estratificado de los datos&#46; Para ello se estudi&#243; la variaci&#243;n de la correlaci&#243;n entre determinaciones seg&#250;n las siguientes variables&#58; existencia o no de patolog&#237;a respiratoria&#59; tipo de ventilaci&#243;n &#40;mec&#225;nica convencional&#44; de alta frecuencia&#44; no invasiva y respiraci&#243;n espont&#225;nea&#41;&#59; asistencia respiratoria alta &#40;definida como PEEP<span class="elsevierStyleHsp" style=""></span>&#8805;<span class="elsevierStyleHsp" style=""></span>8<span class="elsevierStyleHsp" style=""></span>cmH<span class="elsevierStyleInf">2</span>O y&#47;o FiO<span class="elsevierStyleInf">2</span><span class="elsevierStyleHsp" style=""></span>&#8805;<span class="elsevierStyleHsp" style=""></span>0&#44;6&#41; o baja&#59; grado de ventilaci&#243;n &#40;PaCO<span class="elsevierStyleInf">2</span><span class="elsevierStyleHsp" style=""></span>&#60;<span class="elsevierStyleHsp" style=""></span>35<span class="elsevierStyleHsp" style=""></span>mmHg&#59; entre 35<span class="elsevierStyleHsp" style=""></span>&#8211;<span class="elsevierStyleHsp" style=""></span>50<span class="elsevierStyleHsp" style=""></span>mmHg&#59;<span class="elsevierStyleHsp" style=""></span>&#62;<span class="elsevierStyleHsp" style=""></span>50<span class="elsevierStyleHsp" style=""></span>mmHg&#41;&#59; localizaci&#243;n del sensor &#40;frontal&#44; esternal&#44; clavicular o escapular&#41;&#59; y tiempo desde la calibraci&#243;n de membrana &#40;mayor o menor de 20 d&#237;as&#41;&#46;</p></span><span class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle">Resultados</span><p class="elsevierStylePara elsevierViewall">Durante el estudio se siguieron 12 pacientes&#44; 8 varones y 4 mujeres&#46; Con un amplio rango de edades&#44; comprendidas entre 10 d&#237;as y 12&#44;62 a&#241;os y con pesos entre 3&#44;4<span class="elsevierStyleHsp" style=""></span>&#8211;<span class="elsevierStyleHsp" style=""></span>45<span class="elsevierStyleHsp" style=""></span>kg&#46; Las caracter&#237;sticas de los pacientes se resumen en la <a class="elsevierStyleCrossRef" href="#tbl1">tabla 1</a>&#46; Ning&#250;n paciente fue excluido del estudio una vez captado&#46;</p><elsevierMultimedia ident="tbl1"></elsevierMultimedia><p class="elsevierStylePara elsevierViewall">Respecto al diagn&#243;stico de los pacientes&#44; 7 presentaban patolog&#237;a respiratoria &#44; 4 deterioro neurol&#243;gico grave y uno metabolopat&#237;a cong&#233;nita &#40;<a class="elsevierStyleCrossRef" href="#tbl1">tabla 1</a>&#41;&#46;</p><p class="elsevierStylePara elsevierViewall">En los pacientes se recogieron un total de 106 pares de determinaciones&#44; de ellos se excluyeron 6 por problemas t&#233;cnicos en la recogida &#40;1 por calibraci&#243;n incorrecta&#44; 3 por anillo no colocado sobre prominencia &#243;sea&#44; 1 porque no se realiz&#243; en el mismo momento la determinaci&#243;n de PaCO<span class="elsevierStyleInf">2</span> y 1 porque no se recogi&#243; el valor de PtCO<span class="elsevierStyleInf">2</span>&#41;&#46; Con ello el n&#250;mero final de pares de determinaciones fue 100&#46;</p><p class="elsevierStylePara elsevierViewall">En el momento de realizar la determinaci&#243;n el paciente se encontraban en respiraci&#243;n espont&#225;nea en 12 ocasiones y en 88 estaba sometido a ventilaci&#243;n &#40;57 ventilaci&#243;n mec&#225;nica convencional&#44; 19 ventilaci&#243;n no invasiva y 12 ventilaci&#243;n de alta frecuencia&#41;&#46;</p><p class="elsevierStylePara elsevierViewall">La PaCO<span class="elsevierStyleInf">2</span> media de las determinaciones result&#243; 51&#44;0<span class="elsevierStyleHsp" style=""></span>mmHg&#44; con desviaci&#243;n est&#225;ndar de<span class="elsevierStyleHsp" style=""></span>&#177;<span class="elsevierStyleHsp" style=""></span>13<span class="elsevierStyleHsp" style=""></span>mmHg&#46; La PtCO<span class="elsevierStyleInf">2</span> media fue 50&#44;1<span class="elsevierStyleHsp" style=""></span>mmHg&#44; con desviaci&#243;n estandar<span class="elsevierStyleHsp" style=""></span>&#177;<span class="elsevierStyleHsp" style=""></span>14<span class="elsevierStyleHsp" style=""></span>mmHg&#46; Tras comprobar la normalidad de la distribuci&#243;n de los valores se obtuvo un coeficiente r<span class="elsevierStyleSup">2</span><span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>0&#44;87 &#40;p&#60;0&#44;001&#41;&#46; La ecuaci&#243;n obtenida fue&#58; PaCO<span class="elsevierStyleInf">2</span><span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>8&#44;17<span class="elsevierStyleHsp" style=""></span>&#43;<span class="elsevierStyleHsp" style=""></span>0&#44;86<span class="elsevierStyleHsp" style=""></span>&#215;<span class="elsevierStyleHsp" style=""></span>PtCO<span class="elsevierStyleInf">2</span> &#40;<a class="elsevierStyleCrossRef" href="#fig1">fig&#46; 1</a>&#41;&#46; El coeficiente de correlaci&#243;n intraclase para medidas promedio fue 0&#44;96 con IC&#58; 0&#44;94<span class="elsevierStyleHsp" style=""></span>&#8211;<span class="elsevierStyleHsp" style=""></span>0&#44;97 y para medidas individuales 0&#44;92 &#40;IC&#58; 0&#44;88<span class="elsevierStyleHsp" style=""></span>&#8211;<span class="elsevierStyleHsp" style=""></span>0&#44;94&#41;&#46;</p><elsevierMultimedia ident="fig1"></elsevierMultimedia><p class="elsevierStylePara elsevierViewall">El an&#225;lisis de Bland-Altman mostr&#243; una media de las diferencias de<span class="elsevierStyleHsp" style=""></span>&#8722;<span class="elsevierStyleHsp" style=""></span>0&#44;9<span class="elsevierStyleHsp" style=""></span>mmHg &#40;IC&#58;<span class="elsevierStyleHsp" style=""></span>&#8722;<span class="elsevierStyleHsp" style=""></span>2&#44;0&#8211;0&#44;2<span class="elsevierStyleHsp" style=""></span>mmHg&#41;&#46; Con unos l&#237;mites de acuerdo para dos desviaciones est&#225;ndar entre<span class="elsevierStyleHsp" style=""></span>&#8722;<span class="elsevierStyleHsp" style=""></span>11&#44;5<span class="elsevierStyleHsp" style=""></span>mmHg &#40;IC&#58;<span class="elsevierStyleHsp" style=""></span>&#8722;<span class="elsevierStyleHsp" style=""></span>13<span class="elsevierStyleHsp" style=""></span>&#8722;<span class="elsevierStyleHsp" style=""></span>&#8722;<span class="elsevierStyleHsp" style=""></span>9&#44;6<span class="elsevierStyleHsp" style=""></span>mmHg&#41; y 9&#44;7<span class="elsevierStyleHsp" style=""></span>mmHg &#40;IC&#58; 7&#44;8<span class="elsevierStyleHsp" style=""></span>&#8211;<span class="elsevierStyleHsp" style=""></span>11&#44;5<span class="elsevierStyleHsp" style=""></span>mmHg&#41; &#40;<a class="elsevierStyleCrossRef" href="#fig2">fig&#46; 2</a>&#41;&#46;</p><elsevierMultimedia ident="fig2"></elsevierMultimedia><p class="elsevierStylePara elsevierViewall">En el an&#225;lisis estratificado se comprob&#243; una mejor correlaci&#243;n en pacientes sin patolog&#237;a respiratoria&#44; en aquellos con asistencia respiratoria baja&#44; cuando los valores de PaCO<span class="elsevierStyleInf">2</span> eran mayores de 50<span class="elsevierStyleHsp" style=""></span>mmHg y si el sensor se colocaba a nivel frontal &#40;<a class="elsevierStyleCrossRef" href="#tbl2">tabla 2</a>&#41;&#46; La correlaci&#243;n era menor cuando se aproximaba la fecha de caducidad de la membrana indicada por el fabricante&#46;</p><elsevierMultimedia ident="tbl2"></elsevierMultimedia><p class="elsevierStylePara elsevierViewall">En el an&#225;lisis de la varianza entre los pares de determinaciones consecutivas no se encontraron diferencias significativas&#46;</p><p class="elsevierStylePara elsevierViewall">El tiempo de estabilizaci&#243;n necesario para que mediaci&#243;n fuese fiable tras la calibraci&#243;n del sensor oscil&#243; entre 10<span class="elsevierStyleHsp" style=""></span>&#8211;<span class="elsevierStyleHsp" style=""></span>15<span class="elsevierStyleHsp" style=""></span>min&#46;</p><p class="elsevierStylePara elsevierViewall">No se observaron efectos secundarios derivados de la utilizaci&#243;n del anillo para la aplicaci&#243;n del sensor&#44; ni relacionados con el estudio&#46;</p></span><span class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle">Discusi&#243;n</span><p class="elsevierStylePara elsevierViewall">La aparici&#243;n en el mercado de nuevos procedimientos menos cruentos para la determinaci&#243;n de presi&#243;n de CO<span class="elsevierStyleInf">2</span> en sangre&#44; hace necesaria la realizaci&#243;n de estudios para la validaci&#243;n de este instrumental en situaciones reales&#46; Se presentan los resultados del primer estudio realizado con el monitor digital SenTec y el anillo de aplicaci&#243;n del sensor&#44; especialmente indicado para el paciente pedi&#225;trico&#46; Con este primer estudio&#44; de manera independiente del productor&#44; se comprueba la fiabilidad y la adecuaci&#243;n del sistema de detecci&#243;n de la PtCO<span class="elsevierStyleInf">2</span> en el paciente pedi&#225;trico de cualquier edad &#40;el paciente m&#225;s peque&#241;o ten&#237;a 10 d&#237;as y pesaba menos de 4<span class="elsevierStyleHsp" style=""></span>kg&#59; el mayor ten&#237;a 12 a&#241;os y medio y un peso de 45<span class="elsevierStyleHsp" style=""></span>kg&#41;&#46;</p><p class="elsevierStylePara elsevierViewall">La PtCO<span class="elsevierStyleInf">2</span> obtenida mediante monitor digital SenTec con sensor de anillo espec&#237;fico tiene una correlaci&#243;n muy buena con la PaCO2&#44; alcanzando cifras superiores a 0&#44;9 con el coeficiente de correlaci&#243;n intraclase&#46; Se comprob&#243; adem&#225;s que esta correlaci&#243;n se manten&#237;a estable y no aparec&#237;an diferencias en determinaciones consecutivas del mismo paciente&#46; En el an&#225;lisis de Bland-Altman encontramos que la PtCO<span class="elsevierStyleInf">2</span> infraestimaba ligeramente la PaCO<span class="elsevierStyleInf">2</span> en 0&#44;9<span class="elsevierStyleHsp" style=""></span>mmHg de media&#44; lo cual carece de relevancia cl&#237;nica&#46; Sin embargo&#44; los l&#237;mites de acuerdo &#40;entre<span class="elsevierStyleHsp" style=""></span>&#8722;<span class="elsevierStyleHsp" style=""></span>11&#44;5<span class="elsevierStyleHsp" style=""></span>mmHg y<span class="elsevierStyleHsp" style=""></span>&#43;<span class="elsevierStyleHsp" style=""></span>9&#44;7<span class="elsevierStyleHsp" style=""></span>mmHg&#41;&#44; pueden resultar excesivos en situaciones cl&#237;nicas en las cuales en control de la PaCO<span class="elsevierStyleInf">2</span> deba ser estricto&#44; &#40;por ejemplo&#44; si se precisa hiperventilaci&#243;n controlada en situaciones de hipertensi&#243;n intracraneal o hipertensi&#243;n pulmonar&#41;&#46; En estos casos la medici&#243;n de la PtCO<span class="elsevierStyleInf">2</span> puede resultar muy adecuada para vigilar la tendencia y los posibles cambios ante complicaciones respiratorias&#44; hemodin&#225;micas o neurol&#243;gicas Estos resultados concuerdan con los obtenidos en adultos criticamente enfermos con sensor de pinza auricular<a class="elsevierStyleCrossRefs" href="#bib5"><span class="elsevierStyleSup">5&#44;7</span></a>&#46;</p><p class="elsevierStylePara elsevierViewall">La monitorizaci&#243;n continua no invasiva de la PtCO<span class="elsevierStyleInf">2</span> en el paciente cr&#237;tico permite evitar gasometr&#237;as repetidas y podr&#237;a ser de extrema utilidad en los pacientes en los cuales la cateterizaci&#243;n arterial no est&#233; indicada&#44; fuese muy dificultosa o pudiese conllevar efectos secundarios importantes&#46; Adem&#225;s&#44; la medici&#243;n de la PtCO<span class="elsevierStyleInf">2</span> aporta informaci&#243;n continua a tiempo real&#46; Tambi&#233;n resulta muy interesante en situaciones en que la PaCO<span class="elsevierStyleInf">2</span> puede variar de manera importante&#44; como en el destete o tras ajustes de ventilaci&#243;n mec&#225;nica&#46; Parece conveniente y oportuno realizar al menos una primera gasometr&#237;a arterial que sirva de referencia a posteriores mediciones&#46;</p><p class="elsevierStylePara elsevierViewall">En el an&#225;lisis estratificado se encontraron resultados concordantes con otros ya publicados&#46; Resulta razonable que la fiabilidad de los resultados se vea afectada por el tiempo de uso de la membrana&#46; En los estudios realizados con el sensor de pinza auricular tambi&#233;n se ha comprobado mayor diferencia cuando se aproximaba la fecha de cambio de membrana indicada por el fabricante<a class="elsevierStyleCrossRef" href="#bib10"><span class="elsevierStyleSup">10</span></a>&#46; Adem&#225;s se han puesto de manifiesto problemas t&#233;cnicos por err&#243;nea colocaci&#243;n de la membrana en el sensor&#44; da&#241;o de la membrana o aplicaci&#243;n inadecuada del sensor&#44; como se describe en otros art&#237;culos<a class="elsevierStyleCrossRef" href="#bib9"><span class="elsevierStyleSup">9</span></a>&#46; Otra consideraci&#243;n importante es el tiempo necesario para la estabilizaci&#243;n de la medida de PtCO<span class="elsevierStyleInf">2</span> tras aplicar el sensor al paciente&#46; Con el sensor de pinza auricular se recominedan entre 5<a class="elsevierStyleCrossRef" href="#bib12"><span class="elsevierStyleSup">12</span></a><span class="elsevierStyleHsp" style=""></span>&#8211;<span class="elsevierStyleHsp" style=""></span>20<span class="elsevierStyleHsp" style=""></span>min<a class="elsevierStyleCrossRefs" href="#bib5"><span class="elsevierStyleSup">5&#44;9</span></a>&#46; En este estudio el tiempo necesario ha sido de 10<span class="elsevierStyleHsp" style=""></span>&#8211;<span class="elsevierStyleHsp" style=""></span>15<span class="elsevierStyleHsp" style=""></span>min&#46; Todo ello indica la necesidad de cumplir las especificaciones t&#233;cnicas de forma precisa&#44; as&#237; como de realizar un entrenamiento previo al personal&#46;</p><p class="elsevierStylePara elsevierViewall">Se observ&#243; que las mediciones obtenidas mediante ambos m&#233;todos se aproximaban m&#225;s cuando la PCO<span class="elsevierStyleInf">2</span> era m&#225;s alta&#46; Estos resultados son similares a los publicados en adultos&#44; seg&#250;n los cuales la concordancia empeora cuando el paciente est&#225; hiperventilado&#44; indicando un problema para la detecci&#243;n de valores bajos de PCO<span class="elsevierStyleInf">2</span><a class="elsevierStyleCrossRefs" href="#bib4"><span class="elsevierStyleSup">4&#44;5</span></a>&#46; En esta misma l&#237;nea&#44; en el estudio se han observado diferencias seg&#250;n la localizaci&#243;n del sensor&#44; siendo mejor la correlaci&#243;n en la localizaci&#243;n frontal y peor en la esternal&#46; La sensibilidad en la determinaci&#243;n de la PtCO<span class="elsevierStyleInf">2</span> parece estar inversamente relacionada con el espesor del tejido subcut&#225;neo entre la superficie &#243;sea y la piel donde se coloca el sensor&#46; Otras posibles limitaciones de la medici&#243;n de PtCO<span class="elsevierStyleInf">2</span> descritas por varios autores son las debidas a edema&#44; hipoperfusi&#243;n &#40;por bajo gasto cardiaco&#44; hipovolemia o vasoconstricci&#243;n&#41; e hipotermia<a class="elsevierStyleCrossRefs" href="#bib3"><span class="elsevierStyleSup">3&#44;5&#8211;7&#44;15</span></a>&#46; En nuestro estudio no hubo posibilidad de valorar la importancia de estos factores de confusi&#243;n&#44; puesto que un n&#250;mero muy limitado de determinaciones fueron recogidas en situaci&#243;n de inestabilidad hemodinamica&#46;</p><p class="elsevierStylePara elsevierViewall">La mayor correlaci&#243;n observada en ausencia de patolog&#237;a respiratoria y en pacientes en respiraci&#243;n espont&#225;nea debe ser contrastada en nuevos estudios&#44; puesto que no es posible descartar la concurrencia de otros factores de confusi&#243;n como localizaci&#243;n del sensor diferente a la frontal en pacientes graves &#40;por existencia de otras monitorizaciones como el &#237;ndice biespectral o paciente en prono&#41;&#59; hiperventilaci&#243;n en pacientes con asistencia respiratoria&#59; o mayor tiempo de uso de la membrana en pacientes graves&#46;</p><p class="elsevierStylePara elsevierViewall">Respecto al manejo y la seguridad del sensor&#44; el usar temperaturas menores &#40;entre 39<span class="elsevierStyleHsp" style=""></span>&#8211;<span class="elsevierStyleHsp" style=""></span>40<span class="elsevierStyleHsp" style=""></span>&#176;C&#41; permite un uso m&#225;s prolongado en ni&#241;os peque&#241;os&#44; sin los problemas de lesiones cut&#225;neas&#46; Esto&#44; t&#233;cnicamente posibilita tiempos de monitorizaci&#243;n m&#225;s largos&#44; incluso registros nocturnos&#44; puesto que adem&#225;s la calibraci&#243;n de la membrana se realiza cada 8<span class="elsevierStyleHsp" style=""></span>h&#46; As&#237;&#44; adem&#225;s de la monitorizaci&#243;n del paciente en unidad de cuidados intensivos &#40;neonatales y pedi&#225;tricos&#41; se han descrito otros usos de la monitorizaci&#243;n de la PtCO<span class="elsevierStyleInf">2</span>&#58; en el control anest&#233;sico&#44; en estudios respiratorios durante el sue&#241;o&#44; en las revisiones de la ventilaci&#243;n domiciliaria&#44; en pruebas de esfuerzo&#44; en sedoanalgesia para procedimientos&#44; en el transporte inter e intra hospitalario&#44; en el test de apnea en muerte cerebral e incluso para valorar la viabilidad de la piel tras injerto o quemadura&#46;<a class="elsevierStyleCrossRefs" href="#bib1"><span class="elsevierStyleSup">1&#44;3&#44;6&#44;11&#8211;13&#44;15&#44;17&#44;18</span></a>&#46;</p><p class="elsevierStylePara elsevierViewall">En resumen&#44; en opini&#243;n de los autores el monitor digital SenTec&#44; el sensor para la medici&#243;n de la PtCO<span class="elsevierStyleInf">2</span> y el sistema de anillo espec&#237;fico&#44; constituyen una herramienta fiable&#44; segura y f&#225;cil de utilizar en el paciente pedi&#225;trico&#44; cuando se cumplan unos requisitos m&#237;nimos de entrenamiento&#46; La tolerancia es excelente por parte del paciente y del personal que realiza la t&#233;cnica&#46;</p><p class="elsevierStylePara elsevierViewall">Entre las limitaciones del estudio destaca que&#44; aunque se recogieron diversas caracter&#237;sticas cl&#237;nicas en el momento de las mediciones &#40;como la tensi&#243;n arterial&#44; la existencia de edemas&#44; la vasoconstricci&#243;n cut&#225;nea y la temperatura&#41; no se obtuvo un n&#250;mero suficiente de muestras para realizar un estudio estratificado que permita valorar por separado todas estas variables&#44; relevantes en la cl&#237;nica diaria&#46;</p></span><span class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle">Conflicto de intereses</span><p class="elsevierStylePara elsevierViewall">Los autores declaran no tener ning&#250;n conflicto de intereses&#46;</p></span><span class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle">Financiaci&#243;n</span><p class="elsevierStylePara elsevierViewall">Proyecto de investigaci&#243;n modalidad &#171;B&#187;&#44; aprobado para el a&#241;o 2008&#44; seg&#250;n la Resoluci&#243;n de 18 de agosto del a&#241;o 2008&#44; del Director Gerente de la Gerencia Regional de Salud de Castilla y Le&#243;n&#46;</p></span></span>"
    "textoCompletoSecciones" => array:1 [
      "secciones" => array:11 [
        0 => array:2 [
          "identificador" => "xres263155"
          "titulo" => array:5 [
            0 => "Resumen"
            1 => "Objetivo"
            2 => "Material y m&#233;todos"
            3 => "Resultados"
            4 => "Conclusiones"
          ]
        ]
        1 => array:2 [
          "identificador" => "xpalclavsec246813"
          "titulo" => "Palabras clave"
        ]
        2 => array:2 [
          "identificador" => "xres263154"
          "titulo" => array:5 [
            0 => "Abstract"
            1 => "Objective"
            2 => "Material and methods"
            3 => "Results"
            4 => "Conclusion"
          ]
        ]
        3 => array:2 [
          "identificador" => "xpalclavsec246812"
          "titulo" => "Keywords"
        ]
        4 => array:1 [
          "titulo" => "Introducci&#243;n"
        ]
        5 => array:1 [
          "titulo" => "Material y m&#233;todos"
        ]
        6 => array:1 [
          "titulo" => "Resultados"
        ]
        7 => array:1 [
          "titulo" => "Discusi&#243;n"
        ]
        8 => array:1 [
          "titulo" => "Conflicto de intereses"
        ]
        9 => array:1 [
          "titulo" => "Financiaci&#243;n"
        ]
        10 => array:1 [
          "titulo" => "Bibliograf&#237;a"
        ]
      ]
    ]
    "pdfFichero" => "main.pdf"
    "tienePdf" => true
    "fechaRecibido" => "2009-08-30"
    "fechaAceptado" => "2009-10-28"
    "PalabrasClave" => array:2 [
      "es" => array:1 [
        0 => array:4 [
          "clase" => "keyword"
          "titulo" => "Palabras clave"
          "identificador" => "xpalclavsec246813"
          "palabras" => array:5 [
            0 => "Presi&#243;n transcut&#225;nea de di&#243;xido de carbono"
            1 => "Monitorizaci&#243;n"
            2 => "Cuidados intensivos pedi&#225;tricos"
            3 => "Monitorizaci&#243;n de la presi&#243;n de di&#243;xido de carbono"
            4 => "Medici&#243;n de gases arteriales"
          ]
        ]
      ]
      "en" => array:1 [
        0 => array:4 [
          "clase" => "keyword"
          "titulo" => "Keywords"
          "identificador" => "xpalclavsec246812"
          "palabras" => array:5 [
            0 => "Transcutaneous carbon dioxide tension"
            1 => "Monitoring"
            2 => "Paediatric intensive care"
            3 => "Carbonic dioxide tension monitoring"
            4 => "Arterial gas measurement"
          ]
        ]
      ]
    ]
    "tieneResumen" => true
    "resumen" => array:2 [
      "es" => array:2 [
        "titulo" => "Resumen"
        "resumen" => "<span class="elsevierStyleSectionTitle">Objetivo</span><p class="elsevierStyleSimplePara elsevierViewall">Valorar la fiabilidad de la medici&#243;n de la presi&#243;n transcut&#225;nea de di&#243;xido de carbono &#40;PtCO<span class="elsevierStyleInf">2</span>&#41; respecto a la medici&#243;n de la presi&#243;n arterial de di&#243;xido de carbono &#40;PaCO<span class="elsevierStyleInf">2</span>&#41;&#46;</p> <span class="elsevierStyleSectionTitle">Material y m&#233;todos</span><p class="elsevierStyleSimplePara elsevierViewall">Estudio anal&#237;tico&#44; observacional&#44; longitudinal y prospectivo&#46; Cohorte de pacientes ingresados en unidad de cuidados intensivos pedi&#225;tricos&#46; La PtCO<span class="elsevierStyleInf">2</span> se midi&#243; con el monitor digital SenTec&#44; aplicando el sensor con un anillo espec&#237;fico &#40;sensor V-sign&#44; versi&#243;n MDB 04&#46;04&#46;02&#41;&#46; Se recogieron al mismo tiempo la PtCO<span class="elsevierStyleInf">2</span> y PaCO<span class="elsevierStyleInf">2</span>&#46; La significaci&#243;n estad&#237;stica de la asociaci&#243;n se calcul&#243; mediante el test F de Snedecor&#44; el coeficiente de correlaci&#243;n r<span class="elsevierStyleSup">2</span> de Pearson y el coeficiente de correlaci&#243;n intraclase&#46; El grado de acuerdo se estim&#243; con el m&#233;todo de Bland y Altman&#46; La consistencia de los resultados se estudi&#243; con el ANOVA&#46;</p> <span class="elsevierStyleSectionTitle">Resultados</span><p class="elsevierStyleSimplePara elsevierViewall">Se compararon 106 mediciones pareadas de PtCO<span class="elsevierStyleInf">2</span> y PaCO<span class="elsevierStyleInf">2</span>&#44; de 12 pacientes&#46; Las PaCO<span class="elsevierStyleInf">2</span> y PtCO<span class="elsevierStyleInf">2</span> medias fueron 51&#44;0<span class="elsevierStyleHsp" style=""></span>&#177;<span class="elsevierStyleHsp" style=""></span>13<span class="elsevierStyleHsp" style=""></span>mmHg y 50&#44;1<span class="elsevierStyleHsp" style=""></span>&#177;<span class="elsevierStyleHsp" style=""></span>14<span class="elsevierStyleHsp" style=""></span>mmHg&#59; r<span class="elsevierStyleSup">2</span><span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>0&#44;87 &#40;p<span class="elsevierStyleHsp" style=""></span>&#60;<span class="elsevierStyleHsp" style=""></span>0&#44;001&#41;&#44; CCI<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>0&#44;96 &#40;IC&#58; 0&#44;94<span class="elsevierStyleHsp" style=""></span>&#8211;<span class="elsevierStyleHsp" style=""></span>0&#44;97&#41;&#46; El an&#225;lisis de Bland-Altman mostr&#243; una media de las diferencias de<span class="elsevierStyleHsp" style=""></span>&#8722;<span class="elsevierStyleHsp" style=""></span>0&#44;9<span class="elsevierStyleHsp" style=""></span>mmHg &#40;IC&#58;<span class="elsevierStyleHsp" style=""></span>&#8722;<span class="elsevierStyleHsp" style=""></span>2&#44;0 a 0&#44;2<span class="elsevierStyleHsp" style=""></span>mmHg&#41;&#46; La correlaci&#243;n fue mejor en ausencia de patolog&#237;a respiratoria&#44; con asistencia respiratoria baja&#44; con PaCO<span class="elsevierStyleInf">2</span><span class="elsevierStyleHsp" style=""></span>&#62;50<span class="elsevierStyleHsp" style=""></span>mmHg y con aplicaci&#243;n frontal del sensor&#46; Hubo consistencia de los resultados&#46; No se observaron efectos secundarios derivados de la utilizaci&#243;n del anillo&#46;</p> <span class="elsevierStyleSectionTitle">Conclusiones</span><p class="elsevierStyleSimplePara elsevierViewall">La correlaci&#243;n obtenida entre la PtCO<span class="elsevierStyleInf">2</span> y PaCO<span class="elsevierStyleInf">2</span> fue muy buena&#46;El monitor digital SenTec y el sensor de anillo espec&#237;fico constituyen una herramienta fiable&#44; segura y f&#225;cil de utilizar&#46;</p>"
      ]
      "en" => array:2 [
        "titulo" => "Abstract"
        "resumen" => "<span class="elsevierStyleSectionTitle">Objective</span><p class="elsevierStyleSimplePara elsevierViewall">To estimate the accuracy of the transcutaneous carbon dioxide tension measurement &#40;PtCO<span class="elsevierStyleInf">2</span>&#41; compared to the measurement of the arterial carbon dioxide tension &#40;PaCO<span class="elsevierStyleInf">2</span>&#41;&#46;</p> <span class="elsevierStyleSectionTitle">Material and methods</span><p class="elsevierStyleSimplePara elsevierViewall">An analytical&#44; longitudinal&#44; prospective and observational study&#44; of a dynamic cohort taken from the in-patients of a Paediatric Intensive Care Unit &#40;PICU&#41;&#46; The PtCO<span class="elsevierStyleInf">2</span> was measured with the SenTec AG analyzer&#44; and the sensor was applied with the specific Multi-Site Attachment Ring&#46; PtCO<span class="elsevierStyleInf">2</span> and PaCO<span class="elsevierStyleInf">2</span> were recorded at the same time&#46; The statistical significance of the association between paired measurements was evaluated with the Snedecor&#39;s F test&#44; the Pearson&#39;s r<span class="elsevierStyleSup">2</span> correlation coefficient and the Interclass Correlation Coefficient &#40;ICC&#41;&#46; The degree of agreement was evaluated with the Bland &#38; Altman method&#46; The consistency of the results was evaluated with the ANalysis Of the VAriance &#40;ANOVA&#41;&#46;</p> <span class="elsevierStyleSectionTitle">Results</span><p class="elsevierStyleSimplePara elsevierViewall">One hundred and six paired measurements&#44; PtCO<span class="elsevierStyleInf">2</span> and PaCO<span class="elsevierStyleInf">2</span>&#44; from twelve patients&#44; were compared&#46; The means of the PaCO<span class="elsevierStyleInf">2</span> and PtCO<span class="elsevierStyleInf">2</span> were 51&#46;0<span class="elsevierStyleHsp" style=""></span>&#177;13<span class="elsevierStyleHsp" style=""></span>mmHg and 50&#46;1<span class="elsevierStyleHsp" style=""></span>&#177;<span class="elsevierStyleHsp" style=""></span>14<span class="elsevierStyleHsp" style=""></span>mmHg&#44; respectively&#59; r<span class="elsevierStyleSup">2</span><span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>0&#46;87 &#40;p<span class="elsevierStyleHsp" style=""></span>&#60;<span class="elsevierStyleHsp" style=""></span>0&#46;001&#41;&#44; ICC<span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>0&#46;96&#44; &#40;95&#37; CI&#58; 0&#46;94<span class="elsevierStyleHsp" style=""></span>&#8211;<span class="elsevierStyleHsp" style=""></span>0&#46;97&#41;&#46; The Bland-Altman analysis showed a mean difference of<span class="elsevierStyleHsp" style=""></span>&#8722;<span class="elsevierStyleHsp" style=""></span>0&#46;9<span class="elsevierStyleHsp" style=""></span>mmHg &#40;95&#37; CI&#58;<span class="elsevierStyleHsp" style=""></span>&#8722;<span class="elsevierStyleHsp" style=""></span>2&#46;0 to 0&#46;2<span class="elsevierStyleHsp" style=""></span>mmHg&#41;&#46; The correlation was better in cases with no respiratory disease&#44; with low respiratory assistance&#44; with PaCO<span class="elsevierStyleInf">2</span><span class="elsevierStyleHsp" style=""></span>&#62;<span class="elsevierStyleHsp" style=""></span>50<span class="elsevierStyleHsp" style=""></span>mmHg and with the sensor applied on the forehead&#46; The results were consistent&#46; No side effects derived from the use of the ring were observed&#46;</p> <span class="elsevierStyleSectionTitle">Conclusion</span><p class="elsevierStyleSimplePara elsevierViewall">The correlation between PtCO<span class="elsevierStyleInf">2</span> and PaCO<span class="elsevierStyleInf">2</span> is excellent and stable&#46; The ring sensor was safe and easy to use&#46;</p>"
      ]
    ]
    "multimedia" => array:4 [
      0 => array:7 [
        "identificador" => "fig1"
        "etiqueta" => "Figura 1"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr1.jpeg"
            "Alto" => 1519
            "Ancho" => 1637
            "Tamanyo" => 84281
          ]
        ]
        "descripcion" => array:1 [
          "es" => "<p class="elsevierStyleSimplePara elsevierViewall">Correlaci&#243;n entre los valores de presi&#243;n trancut&#225;nea de di&#243;xido de carbono &#40;PtCO<span class="elsevierStyleInf">2</span>&#41; y presi&#243;n arterial de di&#243;xido de carbono &#40;PaCO<span class="elsevierStyleInf">2</span>&#41;&#46; r<span class="elsevierStyleSup">2</span><span class="elsevierStyleHsp" style=""></span>&#61;0&#44;87 &#40;p<span class="elsevierStyleHsp" style=""></span>&#60;<span class="elsevierStyleHsp" style=""></span>0&#46;001&#41;</p>"
        ]
      ]
      1 => array:7 [
        "identificador" => "fig2"
        "etiqueta" => "Figura 2"
        "tipo" => "MULTIMEDIAFIGURA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "figura" => array:1 [
          0 => array:4 [
            "imagen" => "gr2.jpeg"
            "Alto" => 1639
            "Ancho" => 1637
            "Tamanyo" => 130806
          ]
        ]
        "descripcion" => array:1 [
          "es" => "<p class="elsevierStyleSimplePara elsevierViewall">An&#225;lisis de Bland-Altman entre los valores de presi&#243;n trancut&#225;nea de di&#243;xido de carbono &#40;PtCO<span class="elsevierStyleInf">2</span>&#41; y presi&#243;n arterial de di&#243;xido de carbono &#40;PaCO<span class="elsevierStyleInf">2</span>&#41;&#46; L&#237;mites de acuerdo del 95&#37;&#46;</p>"
        ]
      ]
      2 => array:7 [
        "identificador" => "tbl1"
        "etiqueta" => "Tabla 1"
        "tipo" => "MULTIMEDIATABLA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "tabla" => array:2 [
          "leyenda" => "<p class="elsevierStyleSimplePara elsevierViewall">IRA&#58; insuficiencia respiratoria aguda&#59; SC&#58; superficie corporal&#46;</p>"
          "tablatextoimagen" => array:1 [
            0 => array:2 [
              "tabla" => array:1 [
                0 => """
                  <table border="0" frame="\n
                  \t\t\t\t\tvoid\n
                  \t\t\t\t" class=""><thead title="thead"><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-head\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t" style="border-bottom: 2px solid black">&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-head\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t" style="border-bottom: 2px solid black"><span class="elsevierStyleBold">Sexo</span>&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-head\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t" style="border-bottom: 2px solid black"><span class="elsevierStyleBold">Edad &#40;meses&#41;</span>&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-head\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t" style="border-bottom: 2px solid black"><span class="elsevierStyleBold">Peso &#40;kg&#41;</span>&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-head\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t" style="border-bottom: 2px solid black"><span class="elsevierStyleBold">SC &#40;m<span class="elsevierStyleSup">2</span>&#41;</span>&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-head\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t" style="border-bottom: 2px solid black"><span class="elsevierStyleBold">IRA</span>&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-head\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t" style="border-bottom: 2px solid black"><span class="elsevierStyleBold">Diagn&#243;stico principal</span>&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr></thead><tbody title="tbody"><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " rowspan="2" align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">1</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " rowspan="2" align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Var&#243;n</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " rowspan="2" align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">5</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " rowspan="2" align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">4&#44;5</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " rowspan="2" align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;27</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " rowspan="2" align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">s&#237;</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Bronquiolitis&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Displasia broncopulmonar&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">2&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Var&#243;n&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">26&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">14&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;61&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">s&#237;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Neumon&#237;a at&#237;pica&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">3&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Var&#243;n&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">115&#44;5&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">40&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">1&#44;26&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">no&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Encefalomielitis aguda diseminada&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " rowspan="2" align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">4</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " rowspan="2" align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Mujer</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " rowspan="2" align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">3&#44;5</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " rowspan="2" align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">3&#44;4</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " rowspan="2" align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;22</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " rowspan="2" align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">no</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Enfermedad de Wolman&#46;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Transplante de progenitores hematopoy&#233;ticos&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">5&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Mujer&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">13&#44;5&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">10&#44;7&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;51&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">no&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Estatus convulsivo&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">6&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Var&#243;n&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">156&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">45&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">1&#44;322&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">no&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Meningoencefalitis&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">7&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Var&#243;n&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">2&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">4&#44;5&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;26&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">no&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Hemorragia cerebral&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">8&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Mujer&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">35&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">14&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;59&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">s&#237;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Neumon&#237;a aspirativa&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">9&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Mujer&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">93&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">20&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;79&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">s&#237;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Insuficiencia ventilatoria secundaria a atrofia espinal&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">10&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Var&#243;n&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;3&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">3&#44;52&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;22&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">s&#237;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Bronquiolitis&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">11&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Var&#243;n&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">1&#44;5&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">4&#44;5&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;28&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">s&#237;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Bronquiolitis&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">12&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Var&#243;n&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">10&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">7&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;37&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">s&#237;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Traqueobroncomalacia&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr></tbody></table>
                  """
              ]
              "imagenFichero" => array:1 [
                0 => "xTab371592.png"
              ]
            ]
          ]
        ]
        "descripcion" => array:1 [
          "es" => "<p class="elsevierStyleSimplePara elsevierViewall">Caracter&#237;sticas de los pacientes</p>"
        ]
      ]
      3 => array:7 [
        "identificador" => "tbl2"
        "etiqueta" => "Tabla 2"
        "tipo" => "MULTIMEDIATABLA"
        "mostrarFloat" => true
        "mostrarDisplay" => false
        "tabla" => array:2 [
          "leyenda" => "<p class="elsevierStyleSimplePara elsevierViewall">VAFO&#58; ventilaci&#243;n de alta frecuencia&#59; VMC&#58; ventilaci&#243;n mec&#225;nica convencional&#59; VNI&#58; ventilaci&#243;n no invasiva&#46;</p>"
          "tablatextoimagen" => array:1 [
            0 => array:2 [
              "tabla" => array:1 [
                0 => """
                  <table border="0" frame="\n
                  \t\t\t\t\tvoid\n
                  \t\t\t\t" class=""><thead title="thead"><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-head\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t" style="border-bottom: 2px solid black"><span class="elsevierStyleBold">Variable</span>&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-head\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t" style="border-bottom: 2px solid black"><span class="elsevierStyleBold">Categor&#237;as</span>&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-head\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t" style="border-bottom: 2px solid black"><span class="elsevierStyleBold">p</span>&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-head\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t" style="border-bottom: 2px solid black"><span class="elsevierStyleBold">r <span class="elsevierStyleSup">2</span></span>&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-head\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t" style="border-bottom: 2px solid black"><span class="elsevierStyleBold">CCI</span>&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-head\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t" style="border-bottom: 2px solid black"><span class="elsevierStyleBold">IC</span>&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr></thead><tbody title="tbody"><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " rowspan="2" align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Patolog&#237;a respiratoria</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">s&#237;&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">&#60;0&#44;001&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;85&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;99&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;98&#8211;0&#44;99&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">no&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">&#60;0&#44;001&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;98&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;91&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;85&#8211;0&#44;95&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " rowspan="2" align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Asistencia respiratoria</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">baja&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">&#60;0&#44;001&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;92&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;96&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;92&#8211;0&#44;97&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">alta&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">&#60;0&#44;001&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;87&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;92&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;86&#8211;0&#44;96&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " rowspan="4" align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Tipo de ventilaci&#243;n</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">VMC&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">&#60;0&#44;001&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;91&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;95&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;91&#8211;0&#44;97&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">VAFO&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">&#60;0&#44;001&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;94&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;96&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;85&#8211;0&#44;99&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">VNI&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">&#60;0&#44;001&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;83&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;91&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;76&#8211;0&#44;96&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Espont&#225;nea&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">&#60;0&#44;001&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;94&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;97&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;89&#8211;0&#44;99&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " rowspan="3" align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">PaCO<span class="elsevierStyleInf">2</span></td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">&#60;35<span class="elsevierStyleHsp" style=""></span>mmHg&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">&#60;0&#44;05&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;68&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;74&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;62&#8211;0&#44;93&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">35&#8211;50<span class="elsevierStyleHsp" style=""></span>mmHg&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">&#60;0&#44;001&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;67&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;77&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;59&#8211;0&#44;87&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">&#62;50<span class="elsevierStyleHsp" style=""></span>mmHg&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">&#60;0&#44;001&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;84&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;9&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;81&#8211;0&#44;95&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " rowspan="4" align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Localizaci&#243;n sensor</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Frente&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">&#60;0&#44;001&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;97&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;99&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;97&#8211;0&#44;99&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Esc&#225;pula&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">&#60;0&#44;001&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;96&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;98&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;91&#8211;0&#44;99&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Clav&#237;cula&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">&#60;0&#44;001&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;91&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;95&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;87&#8211;0&#44;98&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Estern&#243;n&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">&#60;0&#44;001&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;88&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;93&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;87&#8211;0&#44;96&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " rowspan="2" align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">Tiempo desde cambio membrana</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">&#60;20 d&#237;as&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">&#60;0&#44;001&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;96&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;98&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;96&#8211;0&#44;99&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr><tr title="table-row"><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">&#62;<span class="elsevierStyleHsp" style=""></span>&#61;20 d&#237;as&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">&#60;0&#44;001&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;90&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="char" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;94&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td><td class="td" title="\n
                  \t\t\t\t\ttable-entry\n
                  \t\t\t\t  " align="" valign="\n
                  \t\t\t\t\ttop\n
                  \t\t\t\t">0&#44;90&#8211;0&#44;97&nbsp;\t\t\t\t\t\t\n
                  \t\t\t\t</td></tr></tbody></table>
                  """
              ]
              "imagenFichero" => array:1 [
                0 => "xTab371593.png"
              ]
            ]
          ]
        ]
        "descripcion" => array:1 [
          "es" => "<p class="elsevierStyleSimplePara elsevierViewall">An&#225;lisis de la correlci&#243;n entre PtCO<span class="elsevierStyleInf">2</span> y PaCO<span class="elsevierStyleInf">2</span> por subgrupos &#40;coeficiente de correlaci&#243;n r<span class="elsevierStyleSup">2</span> de Pearson y coeficiente de correlaci&#243;n intraclase&#41;</p>"
        ]
      ]
    ]
    "bibliografia" => array:2 [
      "titulo" => "Bibliograf&#237;a"
      "seccion" => array:1 [
        0 => array:1 [
          "bibliografiaReferencia" => array:18 [
            0 => array:3 [
              "identificador" => "bib1"
              "etiqueta" => "1"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "The current status of transcutaneous blood gas analysis and monitoring"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:1 [
                            0 => "J&#46;W&#46; Severinghaus"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "Blood Gas News"
                        "fecha" => "1998"
                        "volumen" => "7"
                        "paginaInicial" => "4"
                        "paginaFinal" => "9"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            1 => array:3 [
              "identificador" => "bib2"
              "etiqueta" => "2"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "The design&#44; use&#44; and results of transcutaneous carbon dioxide analysis&#58; current and future directions"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:1 [
                            0 => "P&#46; Eberhard"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1213/01.ane.0000278642.16117.f8"
                      "Revista" => array:6 [
                        "tituloSerie" => "Anesth Analg"
                        "fecha" => "2007"
                        "volumen" => "105"
                        "paginaInicial" => "S48"
                        "paginaFinal" => "S52"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/18048898"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            2 => array:3 [
              "identificador" => "bib3"
              "etiqueta" => "3"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Cutaneous carbon dioxide monitoring in adults"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:3 [
                            0 => "P&#46;N&#46; Chhajed"
                            1 => "L&#46; Heuss"
                            2 => "M&#46; Tamm"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Curr Opin Anaesthesiol"
                        "fecha" => "2004"
                        "volumen" => "17"
                        "paginaInicial" => "521"
                        "paginaFinal" => "525"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/17031089"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            3 => array:3 [
              "identificador" => "bib4"
              "etiqueta" => "4"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Performance of a digital PCO<span class="elsevierStyleInf">2</span>&#47;SPO2 ear sensor"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:3 [
                            0 => "S&#46; Kocher"
                            1 => "R&#46; Rohling"
                            2 => "A&#46; Tschupp"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "J Clin Monit Comput"
                        "fecha" => "2004"
                        "volumen" => "18"
                        "paginaInicial" => "75"
                        "paginaFinal" => "79"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/15362268"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            4 => array:3 [
              "identificador" => "bib5"
              "etiqueta" => "5"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Clinical validation of a digital transcutaneous PCO<span class="elsevierStyleInf">2</span>&#47;SpO2 ear sensor in adult patients after cardiac surgery"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:5 [
                            0 => "W&#46; Baulig"
                            1 => "P&#46; Sch&#252;tt"
                            2 => "H&#46;R&#46; Roth"
                            3 => "J&#46; Hayoz"
                            4 => "E&#46;R&#46; Schmid"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1007/s10877-007-9088-6"
                      "Revista" => array:6 [
                        "tituloSerie" => "J Clin Monit Comput"
                        "fecha" => "2007"
                        "volumen" => "21"
                        "paginaInicial" => "303"
                        "paginaFinal" => "309"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/17701383"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            5 => array:3 [
              "identificador" => "bib6"
              "etiqueta" => "6"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Nonivasive monitoring of PaCO<span class="elsevierStyleInf">2</span> during one-lung ventilation and minimal access surgery in adults&#58; End-tidal versus transcutaneus techniques"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:2 [
                            0 => "P&#46; Cox"
                            1 => "J&#46;D&#46; Tobias"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "J Min Access Surg"
                        "fecha" => "2007"
                        "volumen" => "3"
                        "paginaInicial" => "8"
                        "paginaFinal" => "13"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            6 => array:3 [
              "identificador" => "bib7"
              "etiqueta" => "7"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Transcutaneous arterial carbon dioxide pressure monitoring in critically ill adult patients"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:5 [
                            0 => "P&#46; Rodr&#237;guez"
                            1 => "F&#46; Lellouche"
                            2 => "J&#46; Aboab"
                            3 => "C&#46;B&#46; Buisson"
                            4 => "L&#46; Brochard"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1007/s00134-005-0006-4"
                      "Revista" => array:6 [
                        "tituloSerie" => "Intensive Care Med"
                        "fecha" => "2006"
                        "volumen" => "32"
                        "paginaInicial" => "309"
                        "paginaFinal" => "312"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/16450093"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            7 => array:3 [
              "identificador" => "bib8"
              "etiqueta" => "8"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Transcutaneous PCO<span class="elsevierStyleInf">2</span> monitoring during initiation of noninvasive ventilation"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:5 [
                            0 => "J&#46;H&#46; Storre"
                            1 => "B&#46; Steurer"
                            2 => "H&#46;J&#46; Kabitz"
                            3 => "M&#46; Dreher"
                            4 => "W&#46; Windisch"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1378/chest.07-1173"
                      "Revista" => array:6 [
                        "tituloSerie" => "Chest"
                        "fecha" => "2007"
                        "volumen" => "132"
                        "paginaInicial" => "1810"
                        "paginaFinal" => "1816"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/18079217"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            8 => array:3 [
              "identificador" => "bib9"
              "etiqueta" => "9"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Transcutaneous measurement of partial pressure of carbon dioxide and oxygen saturation&#58; validation of the SenTec monitor"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:6 [
                            0 => "C&#46;h&#46; Domingo"
                            1 => "E&#46; Canturri"
                            2 => "M&#46; Luj&#225;n"
                            3 => "A&#46; Moreno"
                            4 => "H&#46; Espuelas"
                            5 => "A&#46; Mar&#237;n"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Arch Bronconeumol"
                        "fecha" => "2006"
                        "volumen" => "42"
                        "paginaInicial" => "246"
                        "paginaFinal" => "251"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/16740241"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            9 => array:3 [
              "identificador" => "bib10"
              "etiqueta" => "10"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Usefulness of transcutaneous carbon dioxide pressure monitoring to measure blood gases in adults hospitalized for respiratory disease"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "A&#46; Herrej&#243;n"
                            1 => "I&#46; Inchaurraga"
                            2 => "J&#46; Palop"
                            3 => "S&#46; Ponce"
                            4 => "R&#46; Peris"
                            5 => "M&#46; Terr&#225;dez"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Arch Bronconeumol"
                        "fecha" => "2006"
                        "volumen" => "42"
                        "paginaInicial" => "225"
                        "paginaFinal" => "229"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/16740237"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            10 => array:3 [
              "identificador" => "bib11"
              "etiqueta" => "11"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Measurement of combined oximetry and cutaneous capnography during flexible bronchoscopy"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "P&#46;N&#46; Chhajed"
                            1 => "R&#46; Rajasekaran"
                            2 => "B&#46; Kaegi"
                            3 => "T&#46;P&#46; Chhajed"
                            4 => "E&#46; Pflimlin"
                            5 => "J&#46; Leuppi"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1183/09031936.06.00088005"
                      "Revista" => array:6 [
                        "tituloSerie" => "Eur Respir J"
                        "fecha" => "2006"
                        "volumen" => "28"
                        "paginaInicial" => "386"
                        "paginaFinal" => "390"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/16641122"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            11 => array:3 [
              "identificador" => "bib12"
              "etiqueta" => "12"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Combined pulse oximetry&#47;cutaneous carbon dioxide tension monitoring during colonoscopies&#58; pilot study with a smart ear clip"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:5 [
                            0 => "L&#46;T&#46; Heuss"
                            1 => "P&#46;N&#46; Chhajed"
                            2 => "P&#46; Schnieper"
                            3 => "T&#46; Hirt"
                            4 => "C&#46; Beglinger"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1159/000081515"
                      "Revista" => array:6 [
                        "tituloSerie" => "Digestion"
                        "fecha" => "2004"
                        "volumen" => "70"
                        "paginaInicial" => "152"
                        "paginaFinal" => "158"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/15479975"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            12 => array:3 [
              "identificador" => "bib13"
              "etiqueta" => "13"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "An evaluation of transcutaneous carbon dioxide partial pressure monitoring during apnea testing in brain-dead patients"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "B&#46; Vivien"
                            1 => "F&#46; Marmion"
                            2 => "S&#46; Roche"
                            3 => "C&#46; Devilliers"
                            4 => "O&#46; Langeron"
                            5 => "P&#46; Coriat"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Anesthesiology"
                        "fecha" => "2006"
                        "volumen" => "104"
                        "paginaInicial" => "701"
                        "paginaFinal" => "707"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/16571965"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            13 => array:3 [
              "identificador" => "bib14"
              "etiqueta" => "14"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Comparaci&#243;n de la fiabilidad de tres monitores de CO<span class="elsevierStyleInf">2</span> transcut&#225;nea en ni&#241;os cr&#237;ticos"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:6 [
                            0 => "J&#46; Urbano Villaescusa"
                            1 => "V&#46; Cruzado Nuevo"
                            2 => "J&#46;M&#46; Bell&#243;n Cano"
                            3 => "J&#46; L&#243;pez-Herce Cid"
                            4 => "M&#46; Herrera L&#243;pez"
                            5 => "A&#46; Carrillo &#193;lvarez"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "An Pediatr &#40;Barc&#41;"
                        "fecha" => "2008"
                        "volumen" => "68"
                        "numero" => "Supl 2"
                        "paginaInicial" => "1"
                        "paginaFinal" => "378"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            14 => array:3 [
              "identificador" => "bib15"
              "etiqueta" => "15"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Carbon dioxide monitoring during long-term noninvasive respiratory support in children"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:6 [
                            0 => "R&#46; Paiva"
                            1 => "U&#46; Krivec"
                            2 => "G&#46; Aubertin"
                            3 => "E&#46; Cohen"
                            4 => "A&#46; Cl&#233;ment"
                            5 => "B&#46; Fauroux"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1007/s00134-009-1408-5"
                      "Revista" => array:6 [
                        "tituloSerie" => "Intensive Care Med"
                        "fecha" => "2009"
                        "volumen" => "35"
                        "paginaInicial" => "1068"
                        "paginaFinal" => "1074"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/19172246"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            15 => array:3 [
              "identificador" => "bib16"
              "etiqueta" => "16"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Statistical methods for assessing agreement between two methods of clinical measurement"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:2 [
                            0 => "J&#46;M&#46; Bland"
                            1 => "D&#46;G&#46; Altman"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Lancet"
                        "fecha" => "1986"
                        "volumen" => "1"
                        "paginaInicial" => "307"
                        "paginaFinal" => "310"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/2563462"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            16 => array:3 [
              "identificador" => "bib17"
              "etiqueta" => "17"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Accuracy and precision of three different methods to determine PCO<span class="elsevierStyleInf">2</span> &#40;PaCO<span class="elsevierStyleInf">2</span> vs&#46; PetCO<span class="elsevierStyleInf">2</span> vs&#46; PtcCO<span class="elsevierStyleInf">2</span>&#41; during interhospital ground transport of critically ill and ventilated adults"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:4 [
                            0 => "J&#46; Hinkelbein"
                            1 => "F&#46; Floss"
                            2 => "C&#46; Denz"
                            3 => "H&#46; Krieter"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1097/TA.0b013e31815eba83"
                      "Revista" => array:6 [
                        "tituloSerie" => "J Trauma"
                        "fecha" => "2008"
                        "volumen" => "65"
                        "paginaInicial" => "10"
                        "paginaFinal" => "18"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/18580512"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            17 => array:3 [
              "identificador" => "bib18"
              "etiqueta" => "18"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Accuracy of Transcutaneous Carbon Dioxide Tension Measurements during Cardiopulmonary Exercise Testing"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:6 [
                            0 => "G&#46; Stege"
                            1 => "F&#46;J&#46; van den Elshout"
                            2 => "Y&#46;F&#46; Heijdra"
                            3 => "M&#46;J&#46; van de Ven"
                            4 => "P&#46;N&#46; Dekhuijzen"
                            5 => "P&#46;J&#46; Vos"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "67466"
                      "Revista" => array:3 [
                        "tituloSerie" => "Respiration"
                        "fecha" => "2008"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/11070455"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
          ]
        ]
      ]
    ]
    "agradecimientos" => array:1 [
      0 => array:2 [
        "titulo" => "Agradecimientos"
        "texto" => "<p class="elsevierStylePara elsevierViewall">A todo el personal de la Unidad de Cuidados Intensivos Pedi&#225;tricos que ha posibilitado con su trabajo la realizaci&#243;n de este estudio&#46;</p>"
      ]
    ]
  ]
  "idiomaDefecto" => "es"
  "url" => "/16954033/0000007200000003/v2_201308271700/S1695403309006894/v2_201308271700/es/main.assets"
  "Apartado" => array:4 [
    "identificador" => "14282"
    "tipo" => "SECCION"
    "es" => array:2 [
      "titulo" => "Originales"
      "idiomaDefecto" => true
    ]
    "idiomaDefecto" => "es"
  ]
  "PDF" => "https://static.elsevier.es/multimedia/16954033/0000007200000003/v2_201308271700/S1695403309006894/v2_201308271700/es/main.pdf?idApp=UINPBA00005H&text.app=https://analesdepediatria.org/"
  "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S1695403309006894?idApp=UINPBA00005H"
]
Compartir
Información de la revista
Vol. 72. Núm. 3.
Páginas 165-171 (marzo 2010)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
15778
Vol. 72. Núm. 3.
Páginas 165-171 (marzo 2010)
Original
Acceso a texto completo
Validación de la medición transcutánea de la presión parcial de dióxido de carbono en el paciente crítico pediátrico
Validation of the transcutaneous carbon dioxide tension measurements in critical paediatric patients
Visitas
15778
S. Fernández de Miguel
Autor para correspondencia
sira007@hotmail.com

Autor para correspondencia.
, M. Gaboli, R. González-Celador, P. Gómez de Quero, V. Murga Herrero, J.M. Sánchez Granados, R. Payo Pérez
Unidad de Críticos y Urgencias Pediátricas, Hospital Universitario de Salamanca, Salamanca, España
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (2)
Tablas (2)
Tabla 1. Características de los pacientes
Tabla 2. Análisis de la correlción entre PtCO2 y PaCO2 por subgrupos (coeficiente de correlación r2 de Pearson y coeficiente de correlación intraclase)
Mostrar másMostrar menos
Resumen
Objetivo

Valorar la fiabilidad de la medición de la presión transcutánea de dióxido de carbono (PtCO2) respecto a la medición de la presión arterial de dióxido de carbono (PaCO2).

Material y métodos

Estudio analítico, observacional, longitudinal y prospectivo. Cohorte de pacientes ingresados en unidad de cuidados intensivos pediátricos. La PtCO2 se midió con el monitor digital SenTec, aplicando el sensor con un anillo específico (sensor V-sign, versión MDB 04.04.02). Se recogieron al mismo tiempo la PtCO2 y PaCO2. La significación estadística de la asociación se calculó mediante el test F de Snedecor, el coeficiente de correlación r2 de Pearson y el coeficiente de correlación intraclase. El grado de acuerdo se estimó con el método de Bland y Altman. La consistencia de los resultados se estudió con el ANOVA.

Resultados

Se compararon 106 mediciones pareadas de PtCO2 y PaCO2, de 12 pacientes. Las PaCO2 y PtCO2 medias fueron 51,0±13mmHg y 50,1±14mmHg; r2=0,87 (p<0,001), CCI=0,96 (IC: 0,940,97). El análisis de Bland-Altman mostró una media de las diferencias de0,9mmHg (IC:2,0 a 0,2mmHg). La correlación fue mejor en ausencia de patología respiratoria, con asistencia respiratoria baja, con PaCO2>50mmHg y con aplicación frontal del sensor. Hubo consistencia de los resultados. No se observaron efectos secundarios derivados de la utilización del anillo.

Conclusiones

La correlación obtenida entre la PtCO2 y PaCO2 fue muy buena.El monitor digital SenTec y el sensor de anillo específico constituyen una herramienta fiable, segura y fácil de utilizar.

Palabras clave:
Presión transcutánea de dióxido de carbono
Monitorización
Cuidados intensivos pediátricos
Monitorización de la presión de dióxido de carbono
Medición de gases arteriales
Abstract
Objective

To estimate the accuracy of the transcutaneous carbon dioxide tension measurement (PtCO2) compared to the measurement of the arterial carbon dioxide tension (PaCO2).

Material and methods

An analytical, longitudinal, prospective and observational study, of a dynamic cohort taken from the in-patients of a Paediatric Intensive Care Unit (PICU). The PtCO2 was measured with the SenTec AG analyzer, and the sensor was applied with the specific Multi-Site Attachment Ring. PtCO2 and PaCO2 were recorded at the same time. The statistical significance of the association between paired measurements was evaluated with the Snedecor's F test, the Pearson's r2 correlation coefficient and the Interclass Correlation Coefficient (ICC). The degree of agreement was evaluated with the Bland & Altman method. The consistency of the results was evaluated with the ANalysis Of the VAriance (ANOVA).

Results

One hundred and six paired measurements, PtCO2 and PaCO2, from twelve patients, were compared. The means of the PaCO2 and PtCO2 were 51.0±13mmHg and 50.1±14mmHg, respectively; r2=0.87 (p<0.001), ICC=0.96, (95% CI: 0.940.97). The Bland-Altman analysis showed a mean difference of0.9mmHg (95% CI:2.0 to 0.2mmHg). The correlation was better in cases with no respiratory disease, with low respiratory assistance, with PaCO2>50mmHg and with the sensor applied on the forehead. The results were consistent. No side effects derived from the use of the ring were observed.

Conclusion

The correlation between PtCO2 and PaCO2 is excellent and stable. The ring sensor was safe and easy to use.

Keywords:
Transcutaneous carbon dioxide tension
Monitoring
Paediatric intensive care
Carbonic dioxide tension monitoring
Arterial gas measurement
Texto completo
Introducción

La posibilidad de monitorizar de forma continua la presión parcial de oxígeno y la presión arterial de dióxido de carbono (PaCO2) usando electrodos térmicos sobre la piel fue descubierta en los años setenta del siglo pasado. La pulsioximetría ha tenido una amplia difusión y disponemos de sistemas transcutáneos fiables con correlación precisa con la saturación arterial de oxígeno. Los sistemas de monitorización transcutánea de dióxido de carbono presentaban problemas técnicos que limitaron su uso1–3.

Para un correcto control de la ventilación lo óptimo es monitorizar la presión de dióxido de carbono (PCO2)4,5. El «gold standard» continúa siendo la PaCO2. Esta determinación, mediante punción o canalización arterial, resulta invasiva, dolorosa y no aporta información en tiempo real; es discontinua, supone un coste elevado y no está exenta de complicaciones. La posibilidad de disponer de un método no invasivo, continuo y fiable de medir o estimar la PaCO2 resultaría de gran ayuda en muchas situaciones clínicas. En la actualidad se utilizan dos técnicas:

  • monitorización del CO2 espirado (PetCO2) mediante capnografía: presenta resultados irregulares con mala correlación en pacientes con patología del parénquima pulmonar, alteración de la relación ventilación-perfusión, en ventilación unipulmonar, obstrucción de vía aérea y en paciente hemodinamicamente inestable. Además la perdida de aire espirado como en presencia de fugas y en la ventilación no invasiva limita sensiblemente esta técnica. También se han descrito variaciones en función de la posición del paciente6–8.

  • medición de la presión transcutánea de CO2 (PtCO2): se basa en la alta solubilidad y difusión del CO2 a través de la piel. Los sistemas actuales utilizan el principio de Severinghaus1 (electrodo sensible a los cambios de pH inducidos por el CO2 en una solución acuosa añadiendo NaHCO2). La medición se realiza colocando sobre la piel un electrodo que calienta hasta una temperatura de 42°C produciendo arteriolización de la sangre3.

En el ámbito pediátrico los sistemas de monitorización de PtCO2 siguen presentando serias limitaciones. Entre ellas destacan: quemaduras en la piel por la temperatura de los electrodos, erosiones cutáneas por alta adhesividad, intervalos de calibración y estabilización largos, necesidad de cambiar electrodos de lugar cada 2–4h y lectura poco fiable en situación de acidosis, vasoconstricción o hipotensión1,2.

Existe actualmente un sistema de monitorización digital, el analizador de PtCO2 SenTec Digital Monitor (distribuido en España por Bioline Supply) que por medio de un sensor digital (V-Sign sensor) permite monitorizar de forma continua la PtCO2, aportando además información sobre la saturación periférica de oxígeno (SpO2) y la frecuencia cardiaca. Se aplica en el lóbulo de la oreja mediante una pinza. Su utilización es sencilla, cómoda, y su tolerancia buena. La experiencia con este monitor y sensor en adultos ha demostrado una buena correlación entre la PaCO2 y la PtCO2, tanto en adultos sanos4 como en adultos con patología respiratoria5,7,9,10. Además se ha utilizado en adultos durante diferentes procedimientos que requerían sedoanalgesia, como broncoscopia11, colonoscopia12, y en ventilación unipulmonar durante toracoscopia6.Por último hay datos relativos a su utilización durante la ventilación no invasiva8 o durante el test de apnea en muerte cerebral13.

En pacientes pediátricos existen escasas publicaciones con este monitor y sensor14,15. El trabajo más extenso se refiere a pacientes mayores de un año sin ventilación mecánica15. Sin embargo, en niños pequeños (especialmente en lactantes y neonatos) la colocación del sensor mediante pinza en el lóbulo auricular presenta problemas por la escasa superficie cutánea para adaptar el sensor.

Recientemente se ha comercializado un anillo específico para la aplicación del sensor en pacientes pediátricos (V-Sign sensor MDB 04.04.02, distribuido en España por Bioline Supply). Dicho anillo puede usarse en todas las edades en diferentes localizaciones cutáneas sobre prominencia ósea (clavicular, esternal, frontal, etc.) siendo por lo tanto más adaptable al paciente pediátrico. Permite la monitorización de la PtCO2 calentando la piel solamente hasta 40°C. Aún no registra la SpO2 ni la frecuencia cardiaca en estas condiciones. Hasta la fecha, según conocimiento de los autores, revisada la literatura, no se han publicado estudios sobre la fiabilidad y seguridad del sistema, ni sobre sus posibles inconvenientes técnicos. El sistema se calibra de forma automática por medio de una concentración conocida de CO2; este proceso requiere pocos minutos. Se puede monitorizar la PtCO2 durante 8h seguidas sin necesidad de repetir la calibración. La membrana del sensor se debe cambiar cada 28 días según instrucciones del fabricante. Permite además el registro completo del estudio para su análisis posterior, por medio de un software específico en un ordenador.

El objetivo principal de este estudio consiste en valorar la fiabilidad de la medición de la PtCO2 respecto a la medición directa de la PaCO2. Se realiza en una cohorte de pacientes pediátricos ingresados en una unidad de cuidados intensivos. Se pretende establecer la correlación, la asociación y el grado de acuerdo entre la PtCO2 y la PaCO2, utilizando el anillo para la aplicación del sensor diseñado especificamente para pacientes pediátricos. Se analiza además si las diferencias individuales entre la PtCO2 y PaCO2 se mantienen constantes.

Como objetivo secundario se plantea verificar si la correlación entre PtCO2 y PaCO2 y la diferencia entre las dos medidas son iguales en diferentes situaciones clínicas y técnicas (localización del sensor, tiempo desde calibración, etc.).

Por último se registran posibles efectos secundarios y problemas técnicos derivados de la utilización del sensor aplicado con anillo.

Material y métodos

El estudio se diseñó como analítico, observacional, longitudinal y prospectivo de cohorte dinámica.

La muestra la constituyeron los pacientes ingresados en la unidad de cuidados intensivos pediátricos entre octubre de 2008 y febrero de 2009. Se tomó como criterio de inclusión la necesidad de cateterización arterial debido a la situación clínica del paciente. Se obtuvo consentimiento informado de los padres o tutores y las correspondientes autorizaciones por parte del comité ético y de la unidad de investigación del centro donde se realizó el estudio.

En cada paciente, cuando su situación clínica precisaba la realización de una gasometría arterial, se realizaban dos determinaciones de PCO2: una transcutánea y otra arterial. Las mediciones de PtCO2 se realizaron con el monitor digital SenTec (versión SMB 06.20.02, Therwill, Suiza) y un sensor especifico aplicado mediante un anillo (sensor V-sign, versión MDB 04.04.02). Dicho sensor calienta la piel hasta 40°C para lograr arterialización de la sangre. Se posiciona a nivel cutáneo sobre prominencia ósea tras añadir una gota de gel difusor. Previo a su aplicación el sensor se calibró según las instrucciones del fabricante. Tras su colocación se esperó un tiempo de 10–15min hasta la correcta estabilización del valor de PtCO2. Las mediciones de PaCO2 se realizaron en un analizador de gases GEM Premium 3.000 (Instrumentation Laboratory). Para evitar sesgos se realizaron sesiones de adiestramiento para la utilización del equipo dirigidas a todo el personal de la unidad.

Además de las presiones de CO2, en cada paciente se recogieron las siguientes variables independientes: edad, sexo, peso, talla, superficie corporal y diagnósticos al ingreso. Así mismo con cada determinación se anotaron los siguientes datos: frecuencia cardiaca, tensión arterial, tipo y dosis de fármacos inotrópicos; saturación periférica de oxígeno; tipo, modalidad y parámetros de asistencia respiratoria; saturación arterial de oxígeno, pH, concentración de ácido láctico y de bicarbonato, exceso de bases, PaO2; localización del sensor, tiempo transcurrido desde la última calibración del sensor y desde el útimo cambio de membrana.

Para el manejo de los datos se creó una base de datos con el programa Access de Microsoft y para el análisis se utilizó el programa SPSS versión 15.0 para Window.

En el análisis de los datos se utilizó la regresión lineal, calculando la significación estadística de la asociación entre determinaciones mediante el test F de Snedecor y el coeficiente de correlación r2 de Pearson. Con el fin de evitar las limitaciones de este coeficiente, se calculó también el coeficiente de correlación intraclase. Cuando la correlación fue significativa, se obtuvo la ecuación de regresión correspondiente. El grado de acuerdo entre las mediciones pareadas se estudió con el método de Bland y Altman16.

La consistencia de los resultados se comprobó analizando el comportamiento de la PtCO2 al variar la PaCO2 entre determinaciones. Para ello se realizó el ANOVA entre las dos primeras medidas de cada paciente así como la correlación entre ellas.

Con el fin de detectar factores que pudieran asociarse o influir en la variación de la correlación PaCO2-PtCO2, y para validar el sistema de medición en diferentes situaciones clínicas, se llevó a cabo un análisis estratificado de los datos. Para ello se estudió la variación de la correlación entre determinaciones según las siguientes variables: existencia o no de patología respiratoria; tipo de ventilación (mecánica convencional, de alta frecuencia, no invasiva y respiración espontánea); asistencia respiratoria alta (definida como PEEP8cmH2O y/o FiO20,6) o baja; grado de ventilación (PaCO2<35mmHg; entre 3550mmHg;>50mmHg); localización del sensor (frontal, esternal, clavicular o escapular); y tiempo desde la calibración de membrana (mayor o menor de 20 días).

Resultados

Durante el estudio se siguieron 12 pacientes, 8 varones y 4 mujeres. Con un amplio rango de edades, comprendidas entre 10 días y 12,62 años y con pesos entre 3,445kg. Las características de los pacientes se resumen en la tabla 1. Ningún paciente fue excluido del estudio una vez captado.

Tabla 1.

Características de los pacientes

  Sexo  Edad (meses)  Peso (kg)  SC (m2)  IRA  Diagnóstico principal 
1Varón54,50,27Bronquiolitis 
Displasia broncopulmonar 
Varón  26  14  0,61  sí  Neumonía atípica 
Varón  115,5  40  1,26  no  Encefalomielitis aguda diseminada 
4Mujer3,53,40,22noEnfermedad de Wolman. 
Transplante de progenitores hematopoyéticos 
Mujer  13,5  10,7  0,51  no  Estatus convulsivo 
Varón  156  45  1,322  no  Meningoencefalitis 
Varón  4,5  0,26  no  Hemorragia cerebral 
Mujer  35  14  0,59  sí  Neumonía aspirativa 
Mujer  93  20  0,79  sí  Insuficiencia ventilatoria secundaria a atrofia espinal 
10  Varón  0,3  3,52  0,22  sí  Bronquiolitis 
11  Varón  1,5  4,5  0,28  sí  Bronquiolitis 
12  Varón  10  0,37  sí  Traqueobroncomalacia 

IRA: insuficiencia respiratoria aguda; SC: superficie corporal.

Respecto al diagnóstico de los pacientes, 7 presentaban patología respiratoria , 4 deterioro neurológico grave y uno metabolopatía congénita (tabla 1).

En los pacientes se recogieron un total de 106 pares de determinaciones, de ellos se excluyeron 6 por problemas técnicos en la recogida (1 por calibración incorrecta, 3 por anillo no colocado sobre prominencia ósea, 1 porque no se realizó en el mismo momento la determinación de PaCO2 y 1 porque no se recogió el valor de PtCO2). Con ello el número final de pares de determinaciones fue 100.

En el momento de realizar la determinación el paciente se encontraban en respiración espontánea en 12 ocasiones y en 88 estaba sometido a ventilación (57 ventilación mecánica convencional, 19 ventilación no invasiva y 12 ventilación de alta frecuencia).

La PaCO2 media de las determinaciones resultó 51,0mmHg, con desviación estándar de±13mmHg. La PtCO2 media fue 50,1mmHg, con desviación estandar±14mmHg. Tras comprobar la normalidad de la distribución de los valores se obtuvo un coeficiente r2=0,87 (p<0,001). La ecuación obtenida fue: PaCO2=8,17+0,86×PtCO2 (fig. 1). El coeficiente de correlación intraclase para medidas promedio fue 0,96 con IC: 0,940,97 y para medidas individuales 0,92 (IC: 0,880,94).

Figura 1.

Correlación entre los valores de presión trancutánea de dióxido de carbono (PtCO2) y presión arterial de dióxido de carbono (PaCO2). r2=0,87 (p<0.001)

(0.08MB).

El análisis de Bland-Altman mostró una media de las diferencias de0,9mmHg (IC:2,0–0,2mmHg). Con unos límites de acuerdo para dos desviaciones estándar entre11,5mmHg (IC:139,6mmHg) y 9,7mmHg (IC: 7,811,5mmHg) (fig. 2).

Figura 2.

Análisis de Bland-Altman entre los valores de presión trancutánea de dióxido de carbono (PtCO2) y presión arterial de dióxido de carbono (PaCO2). Límites de acuerdo del 95%.

(0.12MB).

En el análisis estratificado se comprobó una mejor correlación en pacientes sin patología respiratoria, en aquellos con asistencia respiratoria baja, cuando los valores de PaCO2 eran mayores de 50mmHg y si el sensor se colocaba a nivel frontal (tabla 2). La correlación era menor cuando se aproximaba la fecha de caducidad de la membrana indicada por el fabricante.

Tabla 2.

Análisis de la correlción entre PtCO2 y PaCO2 por subgrupos (coeficiente de correlación r2 de Pearson y coeficiente de correlación intraclase)

Variable  Categorías  p  r 2  CCI  IC 
Patología respiratoriasí  <0,001  0,85  0,99  0,98–0,99 
no  <0,001  0,98  0,91  0,85–0,95 
Asistencia respiratoriabaja  <0,001  0,92  0,96  0,92–0,97 
alta  <0,001  0,87  0,92  0,86–0,96 
Tipo de ventilaciónVMC  <0,001  0,91  0,95  0,91–0,97 
VAFO  <0,001  0,94  0,96  0,85–0,99 
VNI  <0,001  0,83  0,91  0,76–0,96 
Espontánea  <0,001  0,94  0,97  0,89–0,99 
PaCO2<35mmHg  <0,05  0,68  0,74  0,62–0,93 
35–50mmHg  <0,001  0,67  0,77  0,59–0,87 
>50mmHg  <0,001  0,84  0,9  0,81–0,95 
Localización sensorFrente  <0,001  0,97  0,99  0,97–0,99 
Escápula  <0,001  0,96  0,98  0,91–0,99 
Clavícula  <0,001  0,91  0,95  0,87–0,98 
Esternón  <0,001  0,88  0,93  0,87–0,96 
Tiempo desde cambio membrana<20 días  <0,001  0,96  0,98  0,96–0,99 
>=20 días  <0,001  0,90  0,94  0,90–0,97 

VAFO: ventilación de alta frecuencia; VMC: ventilación mecánica convencional; VNI: ventilación no invasiva.

En el análisis de la varianza entre los pares de determinaciones consecutivas no se encontraron diferencias significativas.

El tiempo de estabilización necesario para que mediación fuese fiable tras la calibración del sensor osciló entre 1015min.

No se observaron efectos secundarios derivados de la utilización del anillo para la aplicación del sensor, ni relacionados con el estudio.

Discusión

La aparición en el mercado de nuevos procedimientos menos cruentos para la determinación de presión de CO2 en sangre, hace necesaria la realización de estudios para la validación de este instrumental en situaciones reales. Se presentan los resultados del primer estudio realizado con el monitor digital SenTec y el anillo de aplicación del sensor, especialmente indicado para el paciente pediátrico. Con este primer estudio, de manera independiente del productor, se comprueba la fiabilidad y la adecuación del sistema de detección de la PtCO2 en el paciente pediátrico de cualquier edad (el paciente más pequeño tenía 10 días y pesaba menos de 4kg; el mayor tenía 12 años y medio y un peso de 45kg).

La PtCO2 obtenida mediante monitor digital SenTec con sensor de anillo específico tiene una correlación muy buena con la PaCO2, alcanzando cifras superiores a 0,9 con el coeficiente de correlación intraclase. Se comprobó además que esta correlación se mantenía estable y no aparecían diferencias en determinaciones consecutivas del mismo paciente. En el análisis de Bland-Altman encontramos que la PtCO2 infraestimaba ligeramente la PaCO2 en 0,9mmHg de media, lo cual carece de relevancia clínica. Sin embargo, los límites de acuerdo (entre11,5mmHg y+9,7mmHg), pueden resultar excesivos en situaciones clínicas en las cuales en control de la PaCO2 deba ser estricto, (por ejemplo, si se precisa hiperventilación controlada en situaciones de hipertensión intracraneal o hipertensión pulmonar). En estos casos la medición de la PtCO2 puede resultar muy adecuada para vigilar la tendencia y los posibles cambios ante complicaciones respiratorias, hemodinámicas o neurológicas Estos resultados concuerdan con los obtenidos en adultos criticamente enfermos con sensor de pinza auricular5,7.

La monitorización continua no invasiva de la PtCO2 en el paciente crítico permite evitar gasometrías repetidas y podría ser de extrema utilidad en los pacientes en los cuales la cateterización arterial no esté indicada, fuese muy dificultosa o pudiese conllevar efectos secundarios importantes. Además, la medición de la PtCO2 aporta información continua a tiempo real. También resulta muy interesante en situaciones en que la PaCO2 puede variar de manera importante, como en el destete o tras ajustes de ventilación mecánica. Parece conveniente y oportuno realizar al menos una primera gasometría arterial que sirva de referencia a posteriores mediciones.

En el análisis estratificado se encontraron resultados concordantes con otros ya publicados. Resulta razonable que la fiabilidad de los resultados se vea afectada por el tiempo de uso de la membrana. En los estudios realizados con el sensor de pinza auricular también se ha comprobado mayor diferencia cuando se aproximaba la fecha de cambio de membrana indicada por el fabricante10. Además se han puesto de manifiesto problemas técnicos por errónea colocación de la membrana en el sensor, daño de la membrana o aplicación inadecuada del sensor, como se describe en otros artículos9. Otra consideración importante es el tiempo necesario para la estabilización de la medida de PtCO2 tras aplicar el sensor al paciente. Con el sensor de pinza auricular se recominedan entre 51220min5,9. En este estudio el tiempo necesario ha sido de 1015min. Todo ello indica la necesidad de cumplir las especificaciones técnicas de forma precisa, así como de realizar un entrenamiento previo al personal.

Se observó que las mediciones obtenidas mediante ambos métodos se aproximaban más cuando la PCO2 era más alta. Estos resultados son similares a los publicados en adultos, según los cuales la concordancia empeora cuando el paciente está hiperventilado, indicando un problema para la detección de valores bajos de PCO24,5. En esta misma línea, en el estudio se han observado diferencias según la localización del sensor, siendo mejor la correlación en la localización frontal y peor en la esternal. La sensibilidad en la determinación de la PtCO2 parece estar inversamente relacionada con el espesor del tejido subcutáneo entre la superficie ósea y la piel donde se coloca el sensor. Otras posibles limitaciones de la medición de PtCO2 descritas por varios autores son las debidas a edema, hipoperfusión (por bajo gasto cardiaco, hipovolemia o vasoconstricción) e hipotermia3,5–7,15. En nuestro estudio no hubo posibilidad de valorar la importancia de estos factores de confusión, puesto que un número muy limitado de determinaciones fueron recogidas en situación de inestabilidad hemodinamica.

La mayor correlación observada en ausencia de patología respiratoria y en pacientes en respiración espontánea debe ser contrastada en nuevos estudios, puesto que no es posible descartar la concurrencia de otros factores de confusión como localización del sensor diferente a la frontal en pacientes graves (por existencia de otras monitorizaciones como el índice biespectral o paciente en prono); hiperventilación en pacientes con asistencia respiratoria; o mayor tiempo de uso de la membrana en pacientes graves.

Respecto al manejo y la seguridad del sensor, el usar temperaturas menores (entre 3940°C) permite un uso más prolongado en niños pequeños, sin los problemas de lesiones cutáneas. Esto, técnicamente posibilita tiempos de monitorización más largos, incluso registros nocturnos, puesto que además la calibración de la membrana se realiza cada 8h. Así, además de la monitorización del paciente en unidad de cuidados intensivos (neonatales y pediátricos) se han descrito otros usos de la monitorización de la PtCO2: en el control anestésico, en estudios respiratorios durante el sueño, en las revisiones de la ventilación domiciliaria, en pruebas de esfuerzo, en sedoanalgesia para procedimientos, en el transporte inter e intra hospitalario, en el test de apnea en muerte cerebral e incluso para valorar la viabilidad de la piel tras injerto o quemadura.1,3,6,11–13,15,17,18.

En resumen, en opinión de los autores el monitor digital SenTec, el sensor para la medición de la PtCO2 y el sistema de anillo específico, constituyen una herramienta fiable, segura y fácil de utilizar en el paciente pediátrico, cuando se cumplan unos requisitos mínimos de entrenamiento. La tolerancia es excelente por parte del paciente y del personal que realiza la técnica.

Entre las limitaciones del estudio destaca que, aunque se recogieron diversas características clínicas en el momento de las mediciones (como la tensión arterial, la existencia de edemas, la vasoconstricción cutánea y la temperatura) no se obtuvo un número suficiente de muestras para realizar un estudio estratificado que permita valorar por separado todas estas variables, relevantes en la clínica diaria.

Conflicto de intereses

Los autores declaran no tener ningún conflicto de intereses.

Financiación

Proyecto de investigación modalidad «B», aprobado para el año 2008, según la Resolución de 18 de agosto del año 2008, del Director Gerente de la Gerencia Regional de Salud de Castilla y León.

Agradecimientos

A todo el personal de la Unidad de Cuidados Intensivos Pediátricos que ha posibilitado con su trabajo la realización de este estudio.

Bibliografía
[1]
J.W. Severinghaus.
The current status of transcutaneous blood gas analysis and monitoring.
Blood Gas News, 7 (1998), pp. 4-9
[2]
P. Eberhard.
The design, use, and results of transcutaneous carbon dioxide analysis: current and future directions.
Anesth Analg, 105 (2007), pp. S48-S52
[3]
P.N. Chhajed, L. Heuss, M. Tamm.
Cutaneous carbon dioxide monitoring in adults.
Curr Opin Anaesthesiol, 17 (2004), pp. 521-525
[4]
S. Kocher, R. Rohling, A. Tschupp.
Performance of a digital PCO2/SPO2 ear sensor.
J Clin Monit Comput, 18 (2004), pp. 75-79
[5]
W. Baulig, P. Schütt, H.R. Roth, J. Hayoz, E.R. Schmid.
Clinical validation of a digital transcutaneous PCO2/SpO2 ear sensor in adult patients after cardiac surgery.
J Clin Monit Comput, 21 (2007), pp. 303-309
[6]
P. Cox, J.D. Tobias.
Nonivasive monitoring of PaCO2 during one-lung ventilation and minimal access surgery in adults: End-tidal versus transcutaneus techniques.
J Min Access Surg, 3 (2007), pp. 8-13
[7]
P. Rodríguez, F. Lellouche, J. Aboab, C.B. Buisson, L. Brochard.
Transcutaneous arterial carbon dioxide pressure monitoring in critically ill adult patients.
Intensive Care Med, 32 (2006), pp. 309-312
[8]
J.H. Storre, B. Steurer, H.J. Kabitz, M. Dreher, W. Windisch.
Transcutaneous PCO2 monitoring during initiation of noninvasive ventilation.
Chest, 132 (2007), pp. 1810-1816
[9]
C.h. Domingo, E. Canturri, M. Luján, A. Moreno, H. Espuelas, A. Marín.
Transcutaneous measurement of partial pressure of carbon dioxide and oxygen saturation: validation of the SenTec monitor.
Arch Bronconeumol, 42 (2006), pp. 246-251
[10]
A. Herrejón, I. Inchaurraga, J. Palop, S. Ponce, R. Peris, M. Terrádez, et al.
Usefulness of transcutaneous carbon dioxide pressure monitoring to measure blood gases in adults hospitalized for respiratory disease.
Arch Bronconeumol, 42 (2006), pp. 225-229
[11]
P.N. Chhajed, R. Rajasekaran, B. Kaegi, T.P. Chhajed, E. Pflimlin, J. Leuppi, et al.
Measurement of combined oximetry and cutaneous capnography during flexible bronchoscopy.
Eur Respir J, 28 (2006), pp. 386-390
[12]
L.T. Heuss, P.N. Chhajed, P. Schnieper, T. Hirt, C. Beglinger.
Combined pulse oximetry/cutaneous carbon dioxide tension monitoring during colonoscopies: pilot study with a smart ear clip.
Digestion, 70 (2004), pp. 152-158
[13]
B. Vivien, F. Marmion, S. Roche, C. Devilliers, O. Langeron, P. Coriat, et al.
An evaluation of transcutaneous carbon dioxide partial pressure monitoring during apnea testing in brain-dead patients.
Anesthesiology, 104 (2006), pp. 701-707
[14]
J. Urbano Villaescusa, V. Cruzado Nuevo, J.M. Bellón Cano, J. López-Herce Cid, M. Herrera López, A. Carrillo Álvarez.
Comparación de la fiabilidad de tres monitores de CO2 transcutánea en niños críticos.
An Pediatr (Barc), 68 (2008), pp. 1-378
[15]
R. Paiva, U. Krivec, G. Aubertin, E. Cohen, A. Clément, B. Fauroux.
Carbon dioxide monitoring during long-term noninvasive respiratory support in children.
Intensive Care Med, 35 (2009), pp. 1068-1074
[16]
J.M. Bland, D.G. Altman.
Statistical methods for assessing agreement between two methods of clinical measurement.
Lancet, 1 (1986), pp. 307-310
[17]
J. Hinkelbein, F. Floss, C. Denz, H. Krieter.
Accuracy and precision of three different methods to determine PCO2 (PaCO2 vs. PetCO2 vs. PtcCO2) during interhospital ground transport of critically ill and ventilated adults.
[18]
G. Stege, F.J. van den Elshout, Y.F. Heijdra, M.J. van de Ven, P.N. Dekhuijzen, P.J. Vos.
Accuracy of Transcutaneous Carbon Dioxide Tension Measurements during Cardiopulmonary Exercise Testing.
Respiration, (2008),
Copyright © 2009. Asociación Española de Pediatría
Descargar PDF
Idiomas
Anales de Pediatría
Opciones de artículo
Herramientas
es en

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?